AEG DDLE ÖKO TD 18 Operation And Installation page 31

Fully electronically controlled comfort instantaneous water heater
Hide thumbs Also See for DDLE ÖKO TD 18:
Table of Contents

Advertisement

Available languages

Available languages

8.2 Standard delivery
See Fig. "Appliance layout".
8.3 Customer service mode
You can enable/disable customer service mode by press-
ing the SERVICE button (1) at the back of the user inter-
face (connection to "set T" must be available). Pressing
the ECO button (INFO button, see chapter User interface)
switches the display to the next menu item.
Scroll through the respective submenu by turning the
temperature selector.
8.3.1 Fault menu
This menu is only shown if there is a fault.
Code
Meaning
E1, ELEC
The electronic assembly is faulty.
»
Replace it.
»
E 3, ntc
Check the electrical connection to the outlet
sensor. Replace it if required.
»
E 4, mot
Check the electrical connection to the motor-
ised valve. Replace it if required.
8.3.2 Control menu
Code
Meaning
C 1, 36.5 °C Display of the current inlet temperature. If the
cold water sensor is faulty, a temperature of
1.0 °C appears.
C 2, 47.5 °C Display of the current outlet temperature. If the
outlet sensor is faulty, a temperature of 65.0 °C
appears.
C 3, 6.8 l/min Display of the current flow rate.
C 4, 21.5 kW Display of the current power consumption.
8.3.3 Data menu
Code
Meaning
d 1, 8042
Service - Code for customer service.
d 2, 2341
Number of days the appliance is connected to
the power supply.
d 3, 172 h
Heating time in hours.
d 4, 24 kW
Maximum output in kW. This output may differ
from the rated output. For example if the mains
voltage is not 400 V.
8.3.4 Anti-scalding protection / Temperature limit
menu
Code
Meaning
OFF
Anti-scalding protection / Temperature limit
OFF.
On
Anti-scalding protection / Temperature limit
ON.
31 ... 60 °C
For ON setting - maximum value can be select-
ed at the appliance.
Factory defaults (see chapter "Specification"). After ex-
iting customer service mode, you cannot change the set
maximum temperature via the user interface.
CAUTION Burns
If operating the appliance with preheated water, the
set temperature limit and anti-scalding protection
may be ineffective.
In such cases, limit the temperature at the upstream
central thermostatic valve; see chapter "Special ac-
cessories".
8.4 Installation
The appliance has been prepared at the factory for the
following conditions:
◦ Electrical connection from above; installation on un-
finished walls
◦ Water connection on unfinished walls
The appliance must be fitted vertically, oversink or under-
sink, to a solid wall.
8.5 Installation versions
1
The following installation versions are possible/permis-
sible:
◦ Power supply – unfinished walls - from below
◦ Power supply – finished walls
◦ Priority control
◦ Undersink installation, water connections – from
above
◦ Tap for finished walls
◦ Remote temperature control installation
8.6 Accessories
Special accessories are available at specialist trade
shops.
Direct tap for instantaneous water heaters
ADEo 70 WD - Mono lever mixer tap with bath/shower
changeover
Remote temperature control
FBM Comfort
Installation accessories
Pipe assembly, undersink installation UT 104, connec-
tions: Finished walls, G 3/8, top. Water connections with
12 mm compression fitting.
Universal mounting frame
Mounting frame with electrical wiring. This assembly cre-
ates a gap of 30 mm between the appliance back panel
and the installation wall. This enables the power supply
to be freely routed over unfinished walls behind the ap-
pliance. The appliance depth is increased by 30 mm. The
assembly reduces the protection rating to IP 24 (splash-
proof).
Pipe assembly for offset installation
Universal mounting frame (for technical description, see
Universal mounting frame) and pipe bends for the vertical
offset of the appliance against the water connection by
90 mm downwards.
Pipe assembly for gas water heater
replacement
Universal mounting frame (for technical description, see
Universal mounting frame) and pipe bends for installation
using existing gas water heater connections (cold water
connection on the left; DHW connection on the right).
Load shedding relay LR 1-A
The load shedding relay enables operation with, for ex-
ample, electric storage heaters. The instantaneous water
Installation