  • Page 1 DE Gebrauchsanleitung / Montageanleitung FR Mode d'emploi / Instructions de montage EN Instructions for use / assembly instructions Focus 31938000...
  • Page 2 Deutsch Sicherheitshinweise Symbolerklärung Bei der Montage müssen zur Vermeidung von Kein essigsäurehaltiges Silikon verwenden! Quetsch- und Schnittverletzungen Handschuhe getragen werden. Justierung (siehe Seite 9) Das Produkt darf nur zu Bade-, Hygiene- und Körper- Einstellen der Warmwasserbegrenzung. In reinigungszwecken eingesetzt werden. Verbindung mit Durchlauferhitzern ist eine Große Druckunterschiede zwischen den Kalt- und Warmwassersperre nicht zu empfehlen. Warmwasseranschlüssen müssen ausgeglichen werden. Maße (siehe Seite 5) Montagehinweise Durchflussdiagramm • Vor der Montage muss das Produkt auf Transportschä- (siehe Seite 5) den untersucht werden. Nach dem Einbau werden  keine Transport- oder Oberflächenschäden anerkannt. mit EcoSmart ®  ohne EcoSmart ® • Um die Anschluss-Schläuche überprüfen zu können, Serviceteile (siehe Seite ) muss eine Revisionsöffnung vorhanden sein. • Die Leitungen und die Armatur müssen nach den gülti- gen Normen montiert, gespült und geprüft werden. Bedienung (siehe Seite 8) Hansgrohe empfiehlt, morgens oder nach Technische Daten längeren Stagnationszeiten den ersten hal- Armatur serienmäßig mit EcoSmart (Durch- ®...
  • Page 3: Informations Techniques

    Français Consignes de sécurité Description du symbole Lors du montage, porter des gants de protection Ne pas utiliser de silicone contenant de l'acide acétique! pour éviter toute blessure par écrasement ou coupure. Etalonnage (voir pages 9) Le produit ne doit servir qu'à se laver et à assurer Réglage de la limitation d'eau chaude. En l'hygiène corporelle. liaison avec les chauffe-eau, un blocage de Il est conseillé d'équilibrer les pressions de l'eau l'eau chaude n'est pas recommandable. chaude et froide. Dimensions (voir pages 5) Instructions pour le montage Diagramme du débit • Avant son montage, s'assurer que le produit n'a (voir pages 5) subi aucun dommage pendant le transport Après le  avec EcoSmart ® montage, tout dommage de transport ou de surface  sans EcoSmart ® ne pourra pas être reconnu. Pièces détachées (voir pages ) • Pour des travaux d’entretien prévoir obligatoirement une trappe de visite. Instructions de service • Les conduites et la robinetterie doivent être montés, (voir pages 8) rincés et contrôlés selon les normes en vigueur. Hansgrohe recommande de ne pas utiliser Informations techniques le premier demi-litre le matin ou après une Robinetterie équipée en série d’un EcoSmart période de stagnation prolongée.
  • Page 4: Safety Notes

    English Safety Notes Symbol description Gloves should be worn during installation to prevent Do not use silicone containing acetic acid! crushing and cutting injuries. The product may only be used for bathing, hygienic Adjustment (see page 9) and body cleaning purposes. To adjust the hot water limiter. Using a hot The hot and cold supplies must be of equal pres- water limiter in combination with a continu- sures. ous flow water heater is not recommended. Installation Instructions Dimensions (see page 5) • Prior to installation, inspect the product for transport damages. After it has been installed, no transport or Flow diagram (see page 5) surface damage will be honoured.  with EcoSmart ® • There must be an access door for maintenace.  without EcoSmart ® • The pipes and the fixture must be installed, flushed Spare parts (see page ) and tested as per the applicable standards. Technical Data Operation (see page 8) This mixer series-produced with EcoSmart ® Hansgrohe recommends not to use as drink- (flow limiter) ing water the first half liter of water drawn Operating pressure: max. 1 MPa in the morning or after a prolonged period Recommended operating pressure: 0,1 - 0,5 MPa of non-use.
  • Page 5 Focus 31938000 Focus 31938000 0,50 0,45 0,40 0,35 0,30 0,25 0,20 0,15 0,10 0,05 0,00 9 12 15 18 21 24 27 30 Q = l/min Q = l/sec...
  • Page 6 (7 Nm) SW 19 mm (4 Nm) SW 10 mm...
  • Page 7 SW 22 mm > 2 min SW 22 mm (2 Nm)
  • Page 8 c l i c öffnen / ouvert / open schließen / fermé / close warm / chaud / hot kalt / froid / cold öffnen Handbrause / ouvert Douchette / schließen Handbrause / fermé Douchette / open hand shower close hand shower...
  • Page 9 60 °C 10 °C 0,3 MPa 36°C 38°C 50°C 60°C 43°C 55°C 17 x...
  • Page 10 Focus 31938000 98532000 96338000 97406000 95870000 98154000 (33x2) 95730000 95140000 95008000 98118000 98193000 (9x1,8) (32x2) 97773000 97981000 97979000 97978000 95871000 97736000 97980000 97608000 96016000 96507000...
  • Page 12 DE Reinigungsempfehlung / Garantie / Kontakt FR Recommandation pour le nettoyage / Garanties / Contact EN Cleaning recommendation / Warranty / Contact www.hansgrohe.com/ cleaning-recommendation www.hansgrohe.com/ www.hansgrohe.com/ cleaning-recommendation cleaning-recommendation www.hansgrohe.com/ www.hansgrohe.com/ cleaning-recommendation cleaning-recommendation PA-IX DVGW SVGW WRAS KIWA 31938000 www.hansgrohe.com/ cleaning-recommendation Hansgrohe · Auestraße 5 – 9· D-77761 Schiltach · Telefon +49 (0) 78 36/51-1282 · Telefax +49 (0) 7836/511440 E-Mail: info@hansgrohe.com · Internet: www.hansgrohe.com...