DRYER SAFETY..............................................................................1
INSTALLATION REQUIREMENTS ................................................2
Tools and Parts ............................................................................2
Optional Equipment .....................................................................2
Location Requirements................................................................3
ELECTRIC DRYER POWER HOOKUP .........................................6
Electrical Requirements - U.S.A. Only.........................................6
Electrical Connection - U.S.A. Only.............................................7
VENTING .......................................................................................11
Venting Requirements................................................................11
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
DANGER
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
W10224585A
U.S.A. ONLY

TABLE OF CONTENTS

DRYER SAFETY

Your safety and the safety of others are very important.
Para una version de estas intrucciones en español, visite www.Whirlpool.com
Plan Vent System .......................................................................12
Install Vent System.....................................................................13
INSTALL LEVELING LEGS...........................................................13
CONNECT VENT...........................................................................13
CONNECT INLET HOSE (STEAM MODELS)..............................14
LEVEL DRYER ..............................................................................14
COMPLETE INSTALLATION .......................................................14
TROUBLESHOOTING ..................................................................15
You can be killed or seriously injured if you don't immediately
follow instructions.
You
can be killed or seriously injured if you don't follow
instructions.

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool W10224585A

  • Page 1: Table Of Contents

    All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. Para una version de estas intrucciones en español, visite www.Whirlpool.com W10224585A U.S.A.
  • Page 2: Installation Requirements

    INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. ■ ■ Flat-blade screwdriver Caulking gun and compound (for installing new exhaust ■ #2 Phillips screwdriver vent) ■...
  • Page 3: Location Requirements

    Location Requirements You will need ■ A location that allows for proper exhaust installation. See “Venting Requirements.” ■ A separate 30-amp circuit. ■ If you are using a power supply cord, a grounded electrical outlet located within 2 ft (610 mm) of either side of the dryer. See “Electrical Requirements.”...
  • Page 4 Custom undercounter installation - Dryer only Steam (Electric or Gas) 0" (0 mm) 38" (9652 mm) 1" (25 mm) 27" (686 mm) 1" (25 mm) *Required spacing NOTE: Some models are not recommended for undercounter installation. Closet installation - Dryer only (460 mm) Side view Closet door with vents...
  • Page 5 Recommended installation spacing for cabinet installation NOTE: Some models are not recommended for cabinet installation. ■ For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required. Steam (Electric or Gas) 7" (178 mm) 7"...
  • Page 6: Electric Dryer Power Hookup

    ELECTRIC DRYER POWER HOOKUP It is your responsibility ■ To contact a qualified electrical installer. ■ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70- latest edition and all local codes and ordinances. The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
  • Page 7: Electrical Connection - U.s.a. Only

    Electrical Connection - U.S.A. Only WARNING Fire Hazard Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center terminal (silver). Ground wire (green or bare wire) must be connected to green ground connector.
  • Page 8 ■ Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable. 4. Now complete installation following instructions for your type of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is not available)
  • Page 9 4-wire connection: Direct wire IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections. Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed. Strip 5"...
  • Page 10 2. Connect neutral wire (white or center wire) of power supply cord to the center silver-colored terminal screw of the terminal block. Tighten screw. A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E.
  • Page 11: Venting

    4" (102 mm) heavy metal exhaust vent and clamps must be used. 4" (102 mm) heavy metal exhaust vent Vent products can be purchased from your dealer or by calling Whirlpool Service. For more information, see the “Assistance or Service” section. Rigid metal vent ■...
  • Page 12: Plan Vent System

    Exhaust A and B: Recommended hood styles. C: Acceptable hood style. 4" (102 mm) 4" (102 mm) 4" (102 mm) A. Louvered hood style B. Box hood style C. Angled hood style ■ An exhaust hood should cap the vent to keep rodents and insects from entering the home.
  • Page 13: Install Vent System

    Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside. Determine vent path ■ Select the route that will provide the straightest and most direct path outdoors.
  • Page 14: Connect Inlet Hose (Steam Models)

    CONNECT INLET HOSE (STEAM MODELS) The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses. 1. Turn cold water faucet off and remove washer inlet hose. 2. Remove old rubber washer from inlet hose and replace with new rubber washer provided.
  • Page 15: Troubleshooting

    First try the solutions suggested here and possibly avoid the cost of a service call... Dryer Operation Dryer will not run ■ Has a household fuse blown, or has a circuit breaker tripped? There may be 2 household fuses or circuit breakers for the dryer. Check that both fuses are intact and tight, or that both circuit breakers have not tripped.
  • Page 16 The front of the dryer requires a minimum of 1" (25 mm) of airspace, and, for most installations, the rear of the dryer requires 5" (127 mm). See the Installation Instructions. ® Registered Trademark/TM Trademark of Whirlpool, U.S.A. 10/08 Printed in U.S.A.

This manual is also suitable for: