Bioer GenePure Pro NPA-32P User Manual

Bioer GenePure Pro NPA-32P User Manual

Nucleic acid purification system

Advertisement

GenePure Pro
Nucleic Acid Purification System
NPA-32P
Users' Manual
Ha n g z h o u Bi o e r Te
og y Co . , Lt d .
c h n o l

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GenePure Pro NPA-32P and is the answer not in the manual?

Questions and answers

Summary of Contents for Bioer GenePure Pro NPA-32P

  • Page 1 GenePure Pro Nucleic Acid Purification System NPA-32P Users’ Manual Ha n g z h o u Bi o e r Te og y Co . , Lt d . c h n o l...
  • Page 2 This document contains proprietary information protected by copyright. All rights reserved. Without prior written consent from Hangzhou Bioer Technology Co., Ltd., any part of the manual shall not be duplicated, reproduced or translated into any other languages.
  • Page 3 Otherwise, the guard provided by the machine is likely to be damaged, the rated safety level to be reduced, and the rated operation conditions to be affected. Hangzhou Bioer Technology Co. Ltd. shall not be in any way responsible for the consequences resulted from buyer’s not observing the following requirements.
  • Page 4 Maintained products shall be sent to maintenance department designated by Hangzhou Bioer Technology Co., Ltd. by the user. The freight incurred thereof shall be borne by the user. Hangzhou Bioer Technology Co., Ltd. will bear the freight incurred by returning instrument. (For domestic users only) For maintenance out of warranty period, Hangzhou Bioer Technology Co., Ltd.
  • Page 5 Operation Manual for Automatic Nucleic Acid Purification System conditions, improper application, and unauthorized maintenance or alteration. Hangzhou Bioer Technology Co., Ltd. makes no express warranties other than those which are described herein. Any descriptions in sales promotion under specific conditions shall not create an express warranty that the goods shall conform to such description.
  • Page 6: Table Of Contents

    Contents Chapter I Introduction..........................1 Instrument Features.........................1 APPLICATIONS..........................1 Chapter II Features..........................2 Normal Working Conditions......................2 Transportation and Storage Conditions..................2 Basic Parameters..........................2 Basic Performance..........................3 Software Functions...........................3 Chapter III Preparations........................4 Structure Diagram..........................4 Check before Startup........................5 Placement of 96 deep well plate...................... 5 Startup...............................
  • Page 7: Chapter I Introduction

    DNA, RNA from whole blood, cells, and tissues and so on, so as to save time and labor. Instrument Applications This product can be used for separation and purification of nucleic acid in molecular biology laboratory and clinical laboratory. Hangzhou Bioer Technology Co., Ltd.
  • Page 8: Chapter Ii Features

    Basic Parameters Model NPA-32P Parameters Sample size 32pcs/time Magnetic rod (fixed) 4×8 pcs Sample range 20~1000μl Magnetic bead collection >98% efficiency Most suitable size of magnetic 0.2~1.0μm beads 430*395*435 (L*W*H) Overall dimensions mm Net weight 32.5Kg Hangzhou Bioer Technology Co., Ltd.
  • Page 9: Basic Performance

    Voice prompt function Fault protection and alarm function UV lamp on and timed off Upgrade by U disk Caution: The above software features are for reference only. Bioer reserves the right to change the software without notice. Hangzhou Bioer Technology Co., Ltd.
  • Page 10: Chapter Iii Preparations

    Chapter III Preparations This chapter mainly describes the structure, the functions of screen and keys on the screen, as well as the preparations before the startup. Before the first operation of this instrument, please read this chapter carefully and make sure you are familiar with the contents of this chapter. Structure Diagram ②...
  • Page 11: Check Before Startup

    ①Case Body ③Operating room ④ Where 96 deep well ②Display plate is placed ⑤Closing cover ⑥Power switch ⑦ Standard power ⑧USB interface outlet ⑨Sticker Caution: The fuse seat is fitted with a fuse for which the requirement is: F 250V 6A 520. Fuses must be replaced using products that meet the requirements.
  • Page 12: Chapter Iv Operation Guide

    If there is any abnormal sound or display after the instrument is switched on, or there is a Warning! fault alarm during the instrument self-testing, please switch off the power immediately and contact Bioer.  Ready? Let's get started! Upper computer operating interface a.
  • Page 13 Export, Delete, New, Edit, and Run. Export: Copy the selected file to the default u-disk directory (under the \pcrex\Bioer of u-disk directory). Delete: Delete the selected file from the instrument.
  • Page 14 In the center is the ".ebr "file list that conforms to the file name standard in the default directory of U disk (under the \pcrex\Bioer of u-disk directory) (a legal filename consists of an English letter, a number, and an underscore, and a filename that does not include a suffix is no longer than 12 characters long).
  • Page 15 c. New/edit file User can create new file and edit file the following ways: Click on the new file on the main interface. Click on currently selected file of the device file browsing interface. Click on New button of the device file browsing interface. Click on Edit button of the device file browsing interface.
  • Page 16 Set up the lysis temperature, temperature, lysis heating termination step and elution heating termination step. After setting, click on ok to return to the file editing interface. If the change is to be waived, click on Cancel. By clicking on the selected step area, you will enter the step editing interface, as shown in the following figure.
  • Page 17 The mixing parameter allows user to set up a mixing step for up to three periods. If the mixing step is not to be used, set the time to 00:00. The mixing speed can be selected from the option list by clicking on the mixing steps list.
  • Page 18 A soft keyboard is available for inputting the file name. If the file does not want to be viewed, modified, or run, you can enter a password. Run: Run the current edited file. Save: Save the current edited file. d. Running files After editing and saving the program, you can run the it in the following ways: Click on Run button on the file browsing interface;...
  • Page 19 Pause/Reset: Suspend the experiment and Raise the magnetic rods. e. UV light setting In the operation main interface, click ultraviolet lamp setting to enter the ultraviolet lamp setting interface. After setting ultraviolet lamp turn-on time, click ok to turn to the ultraviolet lamp turn-on time set state interface or click cancel button to return to the main interface.
  • Page 20 h. Language selection In the system settings interface click language into the language settings interface, select Chinese or English, click OK or cancel button to return to the system settings interface. i. Backlight adjustment Click backlight adjustment on the system setting interface to enter the backlight adjustment interface. Turn up/down screen brightness by clicking and dragging the scroll bar, or by clicking certain spot in the horizontal column to modify the position of the indicator sign, and then click ok or cancel to return to the system setting interface.
  • Page 21 j. Motion parameters The parameters in this interface are only used by experienced engineers. Please do not modify the parameters without authorization. k. Prompt tone setting Click the prompt tone to enter the prompt tone setting interface on the main interface. After setting the alarm prompt, the keyboard prompt and the closing prompt, click OK or Cancel button to return to the system setting interface.
  • Page 22 New: Add a new step name tag for English and Numbers only and slip line for up to 12 characters, preferably no more than 8 characters Delete: Delete the selected custom name label. The default name is not removable Clear: Remove all custom name tags, leaving only the default name tags. n.
  • Page 23: Chapter V Fault Analysis And Troubleshooting

    Chapter V Fault Analysis and Troubleshooting This chapter mainly introduces the possible fault phenomena, causes analysis and troubleshooting of this instrument. Fault Analysis and Troubleshooting Serial Fault Phenomenon Cause Solution Power on. Check the power and switch on. Display screen is not on Fuse was blown down.
  • Page 24 H a n g z h o u B i o e r Te c h n o l o g y C o . , L t d . Add.: 1192 Bin An Rd., Hi-Tech (Binjiang) District, Hangzhou City, 310053, China. Tel:(0571)85800535,87774558 Fax:(0571)85800537,87774559 E-mail: overseas@bioer.com.cn www.bioer.com.cn...

Table of Contents