3-wire connection: Power supply cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B
D
A
E
F
C
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Ground prong
D. Spade terminals with upturned ends
E. Neutral (white or center wire)
F. Ring terminals
1. Loosen or remove center terminal block screw.
2. Connect neutral wire (white or center wire) of power supply
cord under center screw of the terminal block. Tighten screw.
B
A
A. Neutral wire (white or center wire)
B. Center terminal block screw
3. Connect the other wires to outer terminal block screws.
Tighten screws.
4. Replace the terminal block cover on the back of the dryer.
5. Tighten strain relief nut.
3-wire connection: Direct Wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 3¹⁄₂" (8.9 cm) of outer covering from end of cable. Strip
insulation back 1" (2.5 cm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw.
Page 10