Code Description
E10 Low set point for condenser fan map 3 (for R22)
E11 Low suction pressure point for condenser fan map 3 (for R22)
E12 High set point for condenser fan map 3 (for R22)
E13 High suction pressure point for condenser fan map 3 (for R22)
E14 Low set point for condenser fan map 4 (for R407C)
E15 Lower suction pressure point for condenser fan map 4 (for R404)
E16 High set point for condenser fan map 4 (for R407C)
E17 High suction pressure point for condenser fan map 4 (for R404)
E18 Low set point for condenser fan map 5 (for R407A)
E19 Low suction pressure point for condenser fan map 5 (for R407A)
E20 High set point for condenser fan map 5 (for R407A)
E21 High suction pressure point for condenser fan map 5 (for R407A)
E22 Low set point for condenser fan map 6 (for R407F)
E23 Low suction pressure point for condenser fan map 6 (for R407F)
E24 High set point for condenser fan map 6 (for R407F)
E25 High suction pressure point for condenser fan map 6 (for R407F)
E26 Low set point for condenser fan map 7 (for R448A)
E27 Low suction pressure point for condenser fan map 7 (for R448A)
E28 High set point for condenser fan map 7 (for R448A)
E29 High suction pressure point for condenser fan map 7 (for R448A)
E30 Low set point for condenser fan map 8 (for R449A)
E31 Low suction pressure point for condenser fan map 8 (for R449A)
E32 High set point for condenser fan map 8 (for R449A)
E33 High suction pressure point for condenser fan map 8 (for R449A)
E34 Low set point for condenser fan map 9 (for R410A)
E35 Low suction pressure point for condenser fan map 9 (for R410A)
E36 High set point for condenser fan map 9 (for R410A)
C6.1.6/0613-0915/E
Range
-40 °C to HT3
-1.5Bar to HP3; -21PSI to HP3
LT3 to 110 °C ; LT3 to 230°F
LP3 to 99.9 Bar; LP3 to 999 PSI
-40 °C to HT4;'-40°F to HT4
-1.5Bar to HP4; -21PSI to HP4
LT4 to 110 °C
LP4 to 99.9 Bar; LP4 to 999 PSI
-40 °C to HT5
-1.5Bar to HP5; -21PSI to HP5
LT5 to 110 °C
LP5 to 99.9 Bar; LP5 to 999 PSI
-40 °C to HT6
-1.5Bar to HP6; -21PSI to HP6
LT6 to 110 °C
LP6 to 99.9 Bar; LP6 to 999 PSI
-40 °C to HT7
-1.5Bar to HP7; -21PSI to HP7
LT7 to 110 °C
LP7 to 99.9 Bar; LP7 to 999 PSI
-40 °C to HT8
-1.5Bar to HP8; -21PSI to HP8
LT8 to 110 °C
LP8 to 99.9 Bar; LP8 to 999 PSI
-40 °C to HT9
-1.5Bar to HP9; -21PSI to HP9
LT9 to 110 °C
Factory Setting
ZXDE ZXME ZXLE
20
N.V.
5.2
N.V.
30
N.V.
6.4
N.V.
10
N.V.
1.3
N.V.
38
N.V.
5.4
N.V.
10
N.V.
2.5
N.V.
27
N.V.
5.3
N.V.
10
N.V.
1.7
N.V.
38
N.V.
6.3
N.V.
10
N.V.
3.3
N.V.
30
N.V.
7.2
N.V.
10
N.V.
3.3
N.V.
30
N.V.
7.2
N.V.
10
N.V.
3.3
N.V.
30
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
N.V.
44

Advertisement

Table of Contents
loading

Table of Contents