Location Requirements; Electrical Requirements - Whirlpool ACS088PR0 Use And Care Manual

Room air conditioners for slider and casement windows
Table of Contents

Advertisement

Available languages

Available languages

Parts needed
If metal casement window installation, a
filler panel will be needed for opening greater than 15 "
(39.4 cm) wide. See "Metal or Wood Casement Window
Installation."
If wood casement window installation, a 1" (2.5 cm) wood
frame will be needed. See "Metal or Wood Casement Window
Installation."
NOTE: The installation of this air conditioner is intended to be
permanent. When installed in an apartment or rental property,
permission to make modifications should be obtained from
owner or landlord of building prior to installation of air
conditioner.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed.
Proper installation is your responsibility. Make sure you have
everything necessary for correct installation.
The location should provide:
A horizontal sliding or casement type window with a minimum
width of 15 " (39.4 cm).
Grounded electrical outlet within 4 ft (122 cm) of where the
power cord exits the air conditioner.
NOTE: Do not use an extension cord.
Free movement of air in room to be cooled.
Adequate window frame assembly and side of structure
support for weight of air conditioner. Air conditioner weighs
approximately 82 lbs (37.2 kg) to 100 lbs (45 kg).
NOTE: Do not install the air conditioner in an area where the front
panel will be exposed to heat sources that will raise the panel
surface temperature above 120°F (50°C).
Window Installation
Window opening measurements:
15 " (39.4 cm) minimum opening width
22" (55.9 cm) minimum opening height
A. 15 " (39.4 cm) minimum
B. 22" (55.9 cm) minimum
4
" (19 mm) wood
A
B

Electrical Requirements

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located on the right-hand side of the cabinet.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power supply cord
Recommended ground method
For your personal safety, this air conditioner must be grounded.
This air conditioner is equipped with a power supply cord having
a grounded 3 prong plug. To minimize possible shock hazard, the
cord must be plugged into a mating, grounded 3 prong outlet,
grounded in accordance with all local codes and ordinances. If a
mating outlet is not available, it is the customer's responsibility to
have a properly grounded 3 prong outlet installed by a qualified
electrical installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 -
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
Wiring requirements
115 volt (103.5 min. -
126.5 max.)
0-12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit
only.