Page 1
Catalog No.BK-C0030 HIGH MULTI CYLINDERS KOGANEI Brand KOGANEI Brand RoHS All products are -Compliant All products are s s s a a r RoHS -Compliant Compact & direct mounting Directly mountable without mounting bracket!
Page 2
HIGH MULTI CYLINDERS HIGH MULTI CYLINDERS Directly mountable without mounting bracket, realizing clean lines by embedded sensor switch. Body through hole for vertical mounting Body mounting tap hole of head-side flange type Body mounting tap hole of rod-side flange type Flat surface mounting with lower height Good for use in tight places embedded type sensor switch...
Page 3
VARIATION Standard cylinders (double acting Standard cylinders (single acting Standard cylinders (single acting type) K push type) K pull type) K I N D E X Features Safety Precautions Handling Instructions and Precautions Standard cylinders (Double acting type, Single acting push type, and Single acting pull type) Order code Non-rotating cylinders R...
Page 4
Safety Precautions (High multi cylinder) Always read these precautions carefully before use. Before selecting and using the products, please read all the "Safety Precautions" carefully to ensure proper product use. The Safety Precautions described below are to help you use the product safely and correctly, and to prevent injury or damage to you, other people, and assets. Be sure to observe these safety precautions together with the following safety regulations of ISO4414 (General rules and safety requirements for systems and their components), and JIS B 8370 (General rules relating to systems).
Page 5
KOGANEI overseas group for details. Always post an "operations in progress" sign for installations, (2) KOGANEI shall not be held responsible for any losses or for adjustments, or other operations, to avoid unintentional any damage to other machinery caused by breakdown, loss supplying of air or electrical power, etc.
When the above inequality is not satisfied, select a reed sen- sor switch without indicator lamp. 2. Do not use Koganei sensor switches with other com- pany's cylinders. The sensor switches are designed for use with our Koganei cylinders only.
Page 7
Safety Precautions (Sensor switch) Always read these precautions carefully before use. Wiring DANGER 1. Prevent nearby moving objects from coming into contact with sensor switches. When the cylinders equipped with sensor switches are mov- ing, or when moving objects are nearby, do not let them come into contact each other.
Page 8
Handling Instructions and Precautions When used 1. Do not place your hands in the cylinder operating direction. General precautions 2. In the initial operation, be cautious against cylinder operating direction. 3. When the cylinder is retracting, be cautious against part of your body Piping not be caught in a gap between the cylinder body and the end plate.
Page 9
Handling Instructions and Precautions Mounting Mounting 1. Any mounting posture is available but the mounting surface 10. Mounting of workpiece should be flat surface. Occurrence of twist or bending when in For the cylinder with guide, a workpiece can be mounted on installation could not only deteriorate the accuracy but also two surfaces.
Page 10
Handling Instructions and Precautions Cylinder with guide - Allowable bending moment Applications exceeding the allowable bending moment may damage the guide portion and deteriorate the accuracy, thereby affecting the operating life. Allowable bending moment N · m [in · lbf] Guide center location B Allowable bending Cylinder...
Page 11
Mounting procedure for the rear piping base For the rear piping base of high multi cylinder with guide, the rear piping base is provided as an accessory when shipping from factory. Assemble the base on the unit in the manner shown below. 1.
High multi cylinder Standard cylinders Symbol Double acting type Single acting pull type Single acting push type Specifications Cylinder bore 10 [0.394] Item 16 [0.630] 20 [0.787] 6 [0.236] Operation type Double acting type, single acting push/pull type Media Double acting type 0.15〜0.7 [22 〜...
Page 13
Standard cylinder order code Operation type Note 2 Sensor switch model Lead wire length (for cylinder with magnet) A: 1000 mm [39 in.] Blank: No sensor switch DA: Double acting type B: 3000 mm [118 in.] SA: Single acting push type G: 300 mm [11.8 in.] with -ZE135: With ZE135 -ZE155: With ZE155...
Page 14
Inner construction Double acting type φ φ φ 6 [0.236] 10 [0.394] , 16 [0.630] ⑩ ② ⑤ ⑦ ⑯ ① ⑥ ③ ⑨ ⑧ ④ ⑩ ⑤ ⑦ ② ① ⑨ ⑥ ③ ⑧ ④ Note: Head cover of φ 16 [0.630] is secured by a snap ring (hard steel). φ...
Page 15
Single acting pull type φ φ φ 6 [0.236] 10 [0.394] , 16 [0.630] ③ ⑨ ⑭ ⑮ ④ ③ ⑬ ⑭ ⑮ ④ Note: Head cover of φ 16 [0.630] is secured by a snap ring (hard steel). φ 20 [0.787] ③...
Page 16
Dimensions for double acting type mm [in.] YMDA × Cylinder bore Stroke CAUTION Dimensions A to D for the stroke 5 mm φ φ φ 6 [0.236] , 10 [0.394] , 16 [0.630] [0.197 in.] of the standard cylinder are 2-M5×0.8 dimensions of the cylinder with magnet.
Page 17
Dimensions for single acting push type mm [in.] YMSA Cylinder bore × Stroke φ φ φ 6 [0.236] , 10 [0.394] , 16 [0.630] M5×0.8 Piping connection port 2-φO D+Stroke A+Stroke B+Stroke C+Stroke ●φ6 [0.236] ●φ10 [0.394] , φ16 [0.630] mm [in.] Standard cylinder Cylinder with magnet...
Page 18
Dimensions for single acting pull type mm [in.] YMTA Cylinder bore × Stroke φ φ φ 6 [0.236] , 10 [0.394] , 16 [0.630] M5×0.8 Piping connection port 2-φO D+Stroke A+(Stroke×2) B+Stroke E+Stroke C+Stroke mm [in.] Standard cylinder Cylinder with sensor Type Symbol Bore...
Page 19
High multi cylinder Non-rotating cylinders Symbol Specifications Cylinder bore 6 [0.236] 10 [0.394] 16 [0.630] 20 [0.787] Item Operation type Double acting type Media 0.2〜0.7 [29〜102] Operating pressure range Mpa [psi.] 0.15〜0.7 [22〜102] 0.1〜0.7 [15〜102] Proof pressure Mpa [psi.] 1.05 [152] Operating temperature range °C [°F] 0〜60 [32〜140]...
Page 20
Non-rotating cylinder order code Operation type Note 2 Lead wire length Sensor switch model (for cylinder with magnet) A: 1000 mm [39 in.] Blank: No sensor switch DAL: Non-rotating double acting type B: 3000 mm [118 in.] G: 300 mm [11.8 in.] with -ZE135: With ZE135 -ZE155: With ZE155 -ZE175: With ZE175...
Page 21
Inner construction φ φ φ 6 [0.236] 10 [0.394] , 16 [0.630] ⑩ ⑮ ⑬ ⑭ ⑤ ⑦ ⑯ ① ② ⑥ ③ ⑨ ⑧ ④ ⑩ ⑮ ⑤ ⑦ ⑭ ⑬ ② ① ⑨ ⑥ ③ ⑧ ④ Note: Head cover of φ 16 [0.630] is secured by a snap ring (hard steel). φ...
Page 22
Dimensions for non-rotating double acting type mm [in.] × YMDAL Cylinder bore Stroke CAUTION Dimensions A to D for the stroke 5 mm [0.197 6 [0.236] , 10 [0.394] , 16 [0.630] φ φ φ in.] of the standard cylinder are dimensions of 2-M5×0.8 Piping connection port the cylinder with magnet.
Page 23
High multi cylinder Cylinders with guides Symbol Specifications Cylinder bore 16 [0.630] 20 [0.787] Item 6 [0.236] 10 [0.394] Operation type Double acting type Media 0.2〜0.7 [29〜102] 0.15〜0.7 [22〜102] Operating pressure range MPa [psi.] 0.1〜0.7 [15〜102] Proof pressure MPa [psi.] 1.05 [152] Operating temperature range °C [°F]...
Page 24
Cylinder with guide order code Note 2 Operation type Sensor switch model Lead wire length (for cylinder with magnet) A: 1000 mm [39 in.] Blank: No sensor switch DAG: Double acting type with guide B: 3000 mm [118 in.] G: 300 mm [11.8 in.] with -ZE135: With ZE135 -ZE155: With ZE155 -ZE175: With ZE175...
Page 25
Inner construction 6 [0.236] 10 [0.394] , 16 [0.630] φ φ φ ① ⑯ ⑪ ⑮ ⑭ ⑥ ⑧ ② ⑫ ⑬ ③ ⑦ ⑩ ⑨ ⑤ ⑲ ⑯ ⑪ ⑮ ⑭ ⑥ ⑧ ④ ⑨ ② ① ⑫ ⑬ ③ ⑦ ⑩...
Page 26
Dimensions for double acting type with guide mm [in.] × YMDAGS Cylinder bore Stroke φ φ φ 6 [0.236] , 10 [0.394] , 16 [0.630] P+Stroke 2-O (rear piping base mounting thread) 2-M5×0.8 D+Stroke Piping connection port (AF) A+Stroke B+Stroke C+Stroke M3×0.5 (with plug)
Page 27
Dimensions for double acting type with guide (with rear piping base) mm [in.] × YMDAGS Cylinder bore Stroke M3×0.5 Extended side piping port O-ring C+Stroke M3×0.5 Retracted side piping port B+Stroke A+Stroke Hexagon socket head screw (for securing rear piping base) Note: Rear piping base, 2 hexagon socket head screws (for securing rear piping base) and 2 O-rings are included with shipment.
Page 28
Note 1: Internal voltage drop varies depending on load current. 2: Measured by Koganei test standards. 3: Lead wire length R: A; 1000 mm [39 in.], B; 3000 mm [118 in.], G; 300 mm [11.8 in.] with M8 connector, ZE175 , ZE275...
Order code - YMDAS Lead wire length A: 1000 mm [39 in.] B: 3000 mm [118 in.] G: 300 mm [11.8 in.] with M8 connector, ZE175, ZE275 only Sensor switch model ZE135: Solid state type, 2-lead wire With indicator lamp, 10 to 28V DC Horizontal lead wire ZE101: Reed switch type, no indicator lamp 5 to 28VDC...
Page 30
Dimensions for sensor switch mm [in.] Vertical lead wire Solid state type (ZE235 , ZE255 , ZE275 ) Reed switch type (ZE201 , ZE202 ) M2.5 slotted set screw M2.5 slotted set screw Note Indicator lamp Indicator lamp φ2.6 [0.102] φ2.6 [0.102] Maximum sensing location Maximum sensing location...
Page 31
8. For use in atmosphere where it may be exposed to water or oil, switches. Therefore, be cautious against load return failure. consult your nearest KOGANEI sales office.
Page 32
Usable minimum cylinder stroke for sensor switch Moving procedure of sensor switch mm [in.] The sensor switch can be moved along with the sensor switch mounting Solid state type Reed switch type groove on the cylinder body by loosing the mounting screw. Cylinder bore Tightening torque of mounting screw should be about 0.1 N·m to 0.2 N·m 2 pieces mounted...
Page 33
Sensor switch mounting position for stroke end detection When the sensor switch is mounted at the position specified in the following diagram (values in the table are reference values), the magnet moves to the maximum sensing location position of the sensor switch at the stroke end. Double acting type Single acting push type Single acting pull type...
• KOGANEI CORP. warrants its products to be free from defects KOGANEI CORP. shall in no way be liable or responsible for in material and workmanship subject to the following provisions. injuries or damage to persons or property arising out of the use or operation of the manufacturer’s product.
Need help?
Do you have a question about the YMDA Series and is the answer not in the manual?
Questions and answers