Ignition Timing Check and Adjustment

6. Cancel settings

When ignition timing correction is nished, cancel the forced rotational speed setting and the distributor mode. Make
sure to do this.
(1) Press the HOME key (S004) for one second or more.
Menu item number "
displayed.
(2) Press the UP (S005) or DOWN (S006) key, displaying the menu item numbers. Select menu item
"
" in the (Figure.26.) The display "
(3) Press the SET key (S007). The LEVEL LED (D053) and TEST/WARNING LED (D052) will be
illuminated, and the status with the engine rotating at the forced (set) speed will be displayed at one-
second intervals, as shown below.
Display
(10.1400)
(11.1400)
(12.0.56)
(13.0.56)
(15.85.0)
(4) Press the SET key (S007) for one second or more.
The TEST/WARNING LED (D052) will go out,
and the forced rotational speed setting mode will be
canceled.
(5) Press the HOME key (S004) for one second or more.
Menu item number "
displayed.
(6) Press the UP (S005) or DOWN (S006) key and select
menu item number "
display "
" (Figure.25) will be
Figure.
26
Forced engine rotational speed (example: 1400 min
Engine rotational speed (example: 1400 min
Compressor inlet pressure (Example: 0.56MPa)
Compressor outlet pressure (Example: 0.56MPa)
Compressor outlet temperature (Example: 85.0°C )
" (Figure.28) will be
" (Figure.29.) The
" (Figure.30) will appear.
Figure.
29
" (Figure.27) will appear.
Item
-1
)
31
Figure.
Figure.
25
25
Figure.
27
-1
)
Figure.
Figure.
28
28
Figure.
30

Advertisement