NEW REVISION: S Safety and Installation Instructions for Europe, Asia, Australia, Latin America and Africa This document applies to SunPower PV Modules Languages: English French German Italian Japanese Spanish Contents of this manual are subject to change without notice. In case of inconsistencies or conflicts between the English version and any other versions of this manual (or document), the English version shall prevail and take control in all respects. For the latest Europe, Asia, Australia, Latin America and Africa please refer to www.sunpower.com/PVInstallGuideIEC ...
Page 2
This manual shall be used in combination with industry recognized Contact your module supplier if maintenance is necessary. best practices. Modules should be installed by certified professionals Save these instructions! only. 1.3 Limited Warranty Electrical Characteristics Module limited warranties are described in the SunPower warranty The module electrical ratings are measured under Standard Test document obtainable at www.sunpower.com. Please read this Conditions (STC) of 1 kW/m² irradiance with AM 1.5 spectrum and a document for more information. cell temperature of 25 °C. SunPower modules have specific electrical Warranties do not apply to any of the following; characteristics as shown on the datasheets. ...
Page 3
SunPower recommends that all wiring be double insulated with a 5.1 Site Considerations minimum rating of 85° C (185° F). All wiring should use flexible copper SunPower modules should be mounted in locations that meet the (Cu) conductors. The minimum size should be determined by the ...
Page 4
1.1. Installers should ensure the clamps are of sufficient strength to allow for the maximum design pressure of the module. Clips and clamps are not provided by SunPower. Clamps that secure to the top of the frame must not deform the top flange. Clamps must apply force collinear with the ‘wall’ of ...
Page 5
Module size type (1&2&3&4) (1&2) (1&2&3&4) (1&2&3&4) (1&2&3&4) 96 cells, P‐ G3 Modules that feature antireflective coated glass are prone to visible Series (Black) finger print marks if touched on the front glass surface. SunPower Not Residential Silver & 50‐350 150‐380 50‐150 recommends handing modules with anti‐reflective glass with gloves applicabl and 104 G4.1 & ...
Page 6
SUNPOWER CORPORATION Safety and Installation Instructions ‐ Document 001‐15497 Rev S Table 2: Module Frame Details Platform Module mounting and ground hole detail Frame Profile RESIDENTIAL G3 FRAME ONLY 96 CELL MODULE FRAME DETAIL SIDE FRAME PROFILE Residential END FRAME PROFILE Modules Method 1: Frame Hole Locations FOR COMMERCIAL (SILVER FRAME) MODULES ONLY, INCLUDES STACKING PINS 96 CELL COMMERCIAL MODULE 128 CELL COMMERCIAL MODULE SIDE FRAME PROFILE 1046 mm 4X Ø4.8 mm 1002 mm Drain Holes 4X Ø 4.8 mm Drain Holes 4X Ø4.2 mm Ground Holes 12X Ø...
Page 7
SUNPOWER CORPORATION Safety and Installation Instructions ‐ Document 001‐15497 Rev S Platform Module mounting and ground hole detail Frame Profile FOR P‐SERIES COMMERCIAL GEN 4.1 FRAME MODULES SIDE FRAME PROFILE 2067 mm 46 mm Commercial Modules END FRAME PROFILE 4X Ø 4.2mm 20X Ø 6.8mm 4X 5.0mm (W) x 15.0mm (L) Ground Holes Mounting Holes SLOT FOR P‐SERIES COMMERCIAL GEN 4.2 FRAME MODULES SIDE FRAME PROFILE 2067 mm 40 mm Commercial ...
Page 8
SUNPOWER CORPORATION Safety and Installation Instructions ‐ Document 001‐15497 Rev S Platform Module mounting and ground hole detail Frame Profile FOR P‐SERIES GEN 4.2 FRAME MODULES ( BLACK) 1690 mm SIDE FRAME PROFILE 1500 mm 1300 mm 1100 mm 32mm Residential END FRAME PROFILE Modules 4X Ø 4.2 8X Ø 6.8 24 mm Ground Holes Mounting Holes FOR 104c GEN 4.2 FRAME MODULES 1690 mm SIDE FRAME PROFILE 1500 mm 1300 mm 1100 mm Residential/ ...