Upflow Model Installed Vertically; Drain Exiting Right Side - Maytag Amana MEC96 Series Installation Instructions Manual

Two-stage, fsp category iv direct or non direct vent air furnace
Table of Contents

Advertisement

#2
#1
#5
#4
#8
#7
#9
#10
Coupling
100 Degree
#11
Elbow
Figure 20
NOTE: Hoses are model specific
and not all hoses will be shipped with all models.
WARNING
E
. U
DGES OF SHEET METAL HOLES MAY BE SHARP
SE GLOVES AS A
.
PRECAUTION WHEN REMOVING HOLE PLUGS
WARNING
HIGH VOLTAGE !
T
,
O AVOID THE RISK OF INJURY
ELECTRICAL SHOCK OR
,
DEATH
THE FURNACE MUST BE ELECTRICALLY
GROUNDED IN ACCORDANCE WITH LOCAL CODES OR IN
,
THEIR ABSENCE
WITH THE LATEST EDITION OF THE
N
E
C
.
ATIONAL
LECTRIC
ODE
WARNING
T
,
,
O AVOID THE RISK OF INJURY
ELECTRICAL SHOCK OR DEATH
THE
FURNACE MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH
,
,
LOCAL CODES OR
IN THEIR ABSENCE
WITH THE LATEST EDITION OF THE
N
E
C
.
ATIONAL
LECTRICAL
ODE

Upflow Model Installed Vertically

The trap and factory installed hoses remain as shipped.
The furnace drain may exit either the right or left side of
the furnace cabinet. Both sides of the cabinet have two
.875” diameter holes which can be used interchangeably
for drain and low voltage wiring purposes. If a higher drain
exit is needed, a .875” diameter hole may be added in the
area shown in Figure 21. Any unused cabinet opening must
be sealed. Do not allow drain hose to sag or trap water.
Acceptable
area for
drain hole.
Side Cut-Out
12”
Right side shown.
3”
Figure 21

Drain Exiting Right Side

1. Locate and Install the 45º pipe / hose drain coupling
from the outside of the cabinet (barbed end goes
in the cabinet) through hole in the right side of the
cabinet and secure with two field supplied #8 self-
tapping screws (see Figure 22).
2. Locate the long drain hose #3 and cut at line “A” .
3. Install large end of hose #3 to trap outlet and secure
with 1.25” clamp.
4. Install smaller end of hose #3 on 45º elbow and secure
with 1” clamp.
5. Refer to Field Supplied Drain section for instructions
on field supplied / installed drain on outlet of furnace
trap.