approx. 4 litres of water to flow. Then plug the mains plug back in.
The appliance is ready again for operation.
2.5.3

Limitation of the water temperature

The temperature of the water leaving the tap for the small water heater
can be mechanically set to stage "1" (approx. 40 °C) or stage "eco"
(approx. 60 °C) (see "Operation", page 9).
3

Technical data

Type
Rated output
Rated capacity
Mixed water quantities 40 °C
(15 °C/85 °C) / (15 °C/85 °C)
Variable temperature adjustment up to
Stand-by power consumption at 65 °C/24 h
Electrical connection
Heat-up time to 60 °C
(supply temperature 12 °C)
Fuse protection
Water connection
Maximum flow
Cable length
Dimensions (Height×Width×Depth)
Weight, filled
Energy efficiency class
Load profile
Annual energy consumption
Daily energy consumption
Sound power level
Hot water heating energy efficiency
4

Operating instructions

• Before using the appliance, please read the instructions
carefully and observe them!
• Important: The appliance may never be exposed to frost!
WARNING:
Risk of electric shock!
If a fault occurs, immediately disconnect the plug from the power
supply!
Immediately shut off the cold water supply to the appliance should
it leak.
Please read and observe the detailed safety instructions at the start
of these instructions!
Operation
The small water heater heats and stores drinking water up to approx. 85 °C.
• The warm water outlet of the small water heater serves for pressure
equalisation and my be connected only to the pressureless batteries
BZ 13051 or BZ 13062 (below basin) or BZ 11113 (above basin).
4.1

Setting the water temperature

• The required outlet temperature from 40 °C to 85 °C can be set with
the rotary selector switch.
or:
Tronic 2500 TO – 6 720 879 724 (2019/10)
Conserving energy
• Set the rotary selector to "eco" to conserve energy.
• Hand over the installation and operating instructions to the user and
explain how the appliance operates.
TR2500TO 10 T
TR2500TO 10 T
Undersink
[kW]
2,2
[l]
10,0
[l]
19
[°C]
85
[kWh/d]
0,3
[V]
220-240
[min]
15
[A]
10
["]
17,2(G3/8A)
[l/min]
10
[m]
0,7
[mm]
460×295×285
[kg]
13,7
A
XXS
[kWh]
486
[kWh]
2,360
[dB]
15
[%]
36,5
• Set the required fixed outlet temperature:
● Cold
Frost protection
1 Approx. 40 °C (soft lock-in)
eco Conserve energy approx. 60 °C (soft lock-in)
3 Hot water approx. 85 °C
The pilot lamp lights up during heat up.
Water drips out of the tap with oversink appliances.
The appliance with be covered more quickly with limescale at higher
temperatures.
Tip: Set the rotary selector switch to "eco" to operate the appliance
economically and to reduce the effects of limescale.
Note: If the appliance has not been used for an extended period,
e. g. during a holiday, allow the water to briefly heat up to stage "3".
4.2
Limitation of the water temperature
Limit the outlet temperature to avoid scalding with hot water:
• Set the rotary selector switch to "●".
• Open the cover of the rotary selector switch.
• Select between "1" = approx. 40 °C or "eco" = approx. 60 °C.
• Close the cover.
TR2500TO 10 B
(CH)
Undersink
Over-sink
1,8
2,2
10,0
10,0
28
19
85
85
0,3
0,3
220-240
220-240
17
14
10
10
17,2(G3/8A)
21,3(G1/2A)
10
10
0,7
0,7
460×295×285
461×295×285
13,7
13,7
A
A
XXS
XXS
526
524
2,484
2,472
15
15
35,1
35,2
Technical data
TR2500TO 10 B
(CH)
Over-sink
1,8
10,0
28
85
0,3
220-240
19
10
21,3(G1/2A)
10
0,7
461×295×285
13,7
A
XXS
520
2,446
15
35,5
9