Advertisement

Fig. 19. Electro Oil Inter B9B Burner.
(15/19 model)
Combustion Head
A
2 mm
10 mm
Draught tube
Nozzle
Output
Dimension
kW
Head Type
15
PL 6/7/21.5/10
17
PL 6/7/21.5/10
19
PL 6/7/21.5/10
To adjust the nozzle position, undo the
locking screw located at the rear of the
nozzle line and rotate the adjusting
disc one turn anti-clockwise to move
forward by 1 mm.
Fig. 20. Electro Oil Inter B11 Burner.
(20/25 model).
Combustion Head
A
8 mm
Draught tube
Nozzle
Output
Combustion Head
kW
20/25
PL 10/4/24/10 x 78 mm
Spark gap
2-2.5 mm
Photocell
Adjusting
disc
Nozzle block
Pressure Adjustment
Screw
A
3 mm
5 mm
Oil pump
5 mm
Air control indicator
Air adjustment screw
(4mm hexagonal head)
Spark gap
1 mm
3-3.5 mm
Nozzle block
Dimension
A
5 mm
Locking screw
21
Combustion head
Transformer
Control box
Lockout reset button