Download Print this page
Wayne ISP40 Operating Instructions And Parts Manual

Wayne ISP40 Operating Instructions And Parts Manual

Ac/dc sump pump system

Advertisement

Quick Links

Operating Instructions and Parts Manual
Limited Warranty
For two years from the date of purchase, Wayne Water Systems ("Wayne") will repair or replace, at its option, for the
original purchaser any part or parts of its Sump Pumps or Water Pumps ("Product") found upon examination by Wayne to be
defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be prepared to
provide the model and serial number when exercising this warranty. All transportation charges on Products or parts
submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect,
improper installation, improper maintenance, or failure to operate in accordance with Wayne's written instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO TWO YEARS FROM THE DATE OF PURCHASE. THIS IS THE
EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENS-
ES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of
incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you
specific legal rights, and you may also have other legal rights which vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne or its
suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or
revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of
substitute products, facilities, services or replacement power, downtime costs, or claims of buyer's customers for such
damages.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST
send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987) for return
authorization and instructions.
DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.
MODEL NO._______________ SERIAL NO.__________________________
INSTALLATION DATE_____________
ATTACH YOUR RECEIPT HERE
www.waynepumps.com
Model ISP40
8
Operating Instructions and Parts Manual
Please completely read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury
and/or property damage! Retain instructions for future reference.
AC/DC Sump Pump System
Record Serial Number here.
(Serial
NOTICE
Number is found on Pump Housing)
salt water, brine, laundry discharge,
water softener, sewage, graywater or
any other application which may
Description
contain caustic chemicals and/or
foreign materials. Pump damage could
The AC/DC Sump Pump System
occur if used in these applications and
includes a submersible sump pump
will void warranty.
and a Power Supply/Battery Charger
WARNING
!
(PS/BC). Backup power is supplied by
two 12 volt batteries (not included).
qualified electrician.
The system is designed for home sump
applications. When an electrical power
outage occurs, the PS/BC automatically
Pump
switches the sump pump to battery
power so it will continue to pump
water. Using LED's (Light Emitting
Diodes), the PS/BC also alerts you to
potential problems.

Safety Guidelines

This manual contains information that
is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
DANGER
!
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates a
WARNING
Figure 1 – System Components
!
potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
Pump Specifications
Caution indicates a
CAUTION
!
potentially
Power supply requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120V, 60 Hz
hazardous situation which, if not
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brushless Integral Processor
avoided, may result in minor or
Normal water removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 GPM @ 10 Feet
moderate injury.
Liquid temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40°F to 120°F
Notice indicates
NOTICE
Circuit requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 amps AC (min)
important
Pump Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
information, that if not followed, may
Pump starts at (factory set) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12" Water Level
cause damage to equipment.
Pump stops at (factory set) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6" Water Level
General Safety
Information
Pump Construction
Do not
DANGER
!
use to
Motor housing, volute, filter cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron
pump flammable or explosive
Impeller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Glass-filled Ryton
fluids such as gasoline, fuel
Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .410 Stainless Steel
oil, kerosene, etc. Do not use
Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
in a flammable and/or explosive
Float switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-position
atmosphere. Personal injury and/or
Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Stainless Steel
property damage could result. Only use
pump to pump clear water.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2007 Wayne Water Systems
For parts, product & service information
visit www.waynewatersystems.com
Model ISP40
This pump is not
If the
DANGER
!
designed to handle
basement
has water or moisture on the
floor, do not walk on wet
area until all power is turned
off. If the shutoff box is in the
basement, call an electrician. Remove
pump and either repair or replace.
Failure to follow this warning could
result in fatal electrical shock.
All wiring must be
performed by a
Battery Jumper Wire
Stainless Steel
AC Circuit
Filter
Breaker
Power
Battery
Supply/
Cables
Battery
Charger
(PS/BC)
Power
Pump
Pump Fuse
Supply/Battery
Power Cord
Charger (PS/BC)
Power Cord
1
/
" high x 9
2
351905-001 3/07
3
/
" base
4
®
1
/
" NPT
2

Advertisement

loading

Summary of Contents for Wayne ISP40

  • Page 1: Safety Guidelines

    Limited Warranty For two years from the date of purchase, Wayne Water Systems (“Wayne”) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship.
  • Page 2 10,000 gallons of water from a basement. Deep cycle marine batteries can also be used. Sealed lead acid batteries cost slightly more, but they can last longer. Wayne offers a 40 amp hour battery, 66900- Total Gallons Pumped* 11,000 22,000...
  • Page 3 The PS/BC is designed for use Working in the DANGER vicinity of lead acid with your Wayne Water System pump. batteries can be dangerous. Before making DO NOT USE for any other purpose. connections or servicing the batteries, read and follow instructions in all applicable instruction manuals.
  • Page 4 2. The PS/BC is only for use on 120 volt Trapped water will freeze and (single-phase), 60 hz service and is damage the pump. equipped with a 3-conductor cord and 3-prong, grounding type plug. www.waynepumps.com Model ISP40 Operating Instructions and Parts Manual Maintenance Maintenance (Continued) Always disconnect DANGER...