5.3

START-UP

5.3.1

GENERAL RULES FOR HANDLING THE SPRAY GUN

➞ See SAFETY REGULATIONS in Chapter 2
5.3.2

PREPARATION

Mount the spraygun on the automatic movement system.
Connect material hose to the spraygun and the paint pump.
Select and mount the required nozzle.
Connect the air hose ø6 mm; 0.24 in / ø4 mm; 0.16 in for the control air to the air
connection of the spraygun.
Visually check the permissible pressures for all the system components.
Make sure that the spraying unit and all other conductive parts within the work area
are earthed
Set material pressure approx. 250 bar; 25 MPa; 3626 psi or 400 bar; 40 MPa; 5800 psi
and use a suitable medium (solvent or water) to check that connections do not leak.
Relieve spray gun and unit pressure.