CONTENTS Notice Tools Required Measurements Scope of Application Control Unit Installation Digital Mixer Installation Connecting the Flow Controller Operational Test Troubleshooting Warranty SMARTFLOW INSTALLATION GUIDE...
Installation must be carried out by qualified installers in accordance to this installation manual. AS/NZS3500 standards, rules and safety regulations do apply. PLACE OF INSTALLATION The Tate Digital Controller must be installed in an accessible place and in accordance to this installation manual. This ensures a problem-free service and maintenance procedure. DANGER OF ELECTRIC SHOCK! ELECTRICAL INSTALLATION Before opening the housing, the mains connection must be switched off.
BOX 1 DIGITAL MIXER *3. Flow Control Unit *Supplied with Shower Mixer or available as an optional purchase 2. 12V AC Adaptor (Cable length: 1m) 1. Temperature Control Unit 4. Set of Screws: 2x 5x50mm 5. Adaptor set 6. 2x M10 Hose 450mm (supplied) BOX 2 CONTROL UNIT 5.
Warning: Please ensure that all electrical installations are installed by a registered electrician and complies with the Electrical Hot in Cold in (Safety) Regulations of NZ. Important: The Digital Mixer must have an access panel. FELTON...
CONTROL UNIT INSTALLATION *This Control Unit can also be installed as a Wall Mounted unit or a Deck Mounted unit Conduit Hole Drill Data Cable must be installed prior to the Prepare a Ø30mm hole in the Cut Position wall lining. finished wall, deck or counter/ It is recommended vanity.
Page 8
Apply a silicone bead on the Tube into the hole until the back of the Control Housing, front flange sits against the then push the Control Housing wall. into the Plastic Tube until it is firmly fitted on the unit. FELTON...
Page 9
Tighten the screw inside the Control Housing and ensure the screw is aligned with the Plastic Mounting Tube. This tightens the lugs on the inside of the wall. Tighten until there is no rotation of the Control Housing. Pull the red strip to release the connector from the plastic sleeve.
Page 10
Thread in the cable and fit the Control Wheel onto the Housing. Fit the Control Sleeve onto the Control Wheel. SIDE VIEW Ensure that you fit the Control Sleeve in the correct orientation. FELTON...
DIGITAL MIXER INSTALLATION Remove the cover Inside the Temperature Control Unit Control unit Fixing holes Transformer 12V Cover retaining holes Fixing hole Cold Outlet Inlets SMARTFLOW INSTALLATION GUIDE...
Page 12
MOUNTING OPTIONS MOUNTING FOR NOG 56 mm 99 mm If installed vertically, use orientation Install the Digital Mixer Mark fixing holes shown MOUNTING FOR CONCRETE 56 mm 99 mm ø 5 mm Install the Digital Mixer Drill fixing holes Install the Digital Mixer FELTON...
Page 13
Connect adapters and fit large retaining bolt with torx screw driver supplied. Large retaining bolt ADVICE: Push in firmly! Connect the M10 flexi hoses with the MF adaptors and filters to the water supply feed M10 flexi hoses SMARTFLOW INSTALLATION GUIDE...
Connect the Data Cable coming from the Control Unit. Use the large 6 pin connector and push firmly into the socket. Feed the cable through the one of the guide slots in the front of the Digital Mixer. Data Cable connection FELTON...
Page 15
Connect the power cable coming from the transformer. Use the connector and push firmly into the socket. Feed the cable through the guide slot in the front of the Digital Mixer. Power cable connection SMARTFLOW INSTALLATION GUIDE...
Page 16
Please see User Guide. Digital Mixer with Flow Control Unit installed: Power cable connection IMPORTANT: Fit cables into slots to allow cover to properly close at end of installation IMPORTANT: Electrical supply must be installed by a qualified electrician. FELTON...
OPERATIONAL TEST 1 Ensure that the Digital Mixer is installed correctly installed according to the instructions above. Turn on the water supply and check the unit and plumbing for leaks. Once the plumbing is confirmed to be water-tight, connect the power suply and conduct the operational test below. Digital Mixer with Flow Control Unit installed 2 Open Close...
*Important: Controlling the flow rate is only possible with the Smartflow Digital Shower Mixer, or if you have installed a Digital Flow Control Unit for your Digital Wall Mounted Basin/Bath Mixer or Digital Deck Mounted Sink Mixer. If issue persists or is not covered in the above, please contact our Felton Technical Team on 0800 743 358 or info@felton.co.nz...
WARRANTY 5 year warranty applies to all Felton branded products including the electronic hardware and its components. Where products are promoted as having a “5 year warranty”, Felton Industries Limited guarantees the electronic components of these products (excluding batteries) to be free from defects in materials and workmanship under normal installation, use and service for a period of five (5) years from the date of purchase.
Page 20
. c o . n z | F i n d u s o n S o c i a l M e d i a @feltontapware /feltonltd /FeltonIndustriesLimited @feltonltd /felton-industries-limited 280820HM...
Need help?
Do you have a question about the TATE and is the answer not in the manual?