Download Print this page

Installation - Bosch CP156B Installer's Reference Manual

External metal keypad with smart card reader

Advertisement

Installation

The keypad should be installed onto a solid surface using suitable mount-
ing fixtures. Wiring should only be performed while the control panel is
powered down.
Step 1) Mark out the location of the mounting holes and the cable exit hole
before drilling out all points as necessary. Secure the mounting
plate with appropriate fasteners.
Step 2) Use the connection diagram [Figure 8] to terminate the supplied
cable as required. Unused wires should be insulated to prevent
short circuits.
Step 3) On the PCB use the dip switch to set the required address using
[table 2] Note Each keypad on the system must have a unique
address.
Step 4) Attach the connection cable to the keypad by plugging in the con-
nector. Note the connector is polarised and will only plug in when
correctly aligned. Do not use excessive force.
Step 5) Make sure the cable grommet is fitted correctly to insure a correct
water resistant seal.
Step 6) Carefully hook the keypad to the back plate and fit the Hex screw
using the allen key supplied.
See figure 6.
Mounting
Holes x 2
Figure 4: Backing Plate Rear View
Bosch Security Systems
01/19 CP156BIRG FTR1.1
Rubber
Grommet
Pre-Instlled
Figure 5: Side View Showing
Grommet Installation
CP156B
Installer Reference Guide
CP156B Mounting Template
4.50mm (11/64")
maximum hole
14.0mm (1") minimum
hole size
4.50mm (11/64")
maximum hole
Figure 3: Mounting Template (Not to Scale)
CP156 Mounting Template.ai
1 hex screw
Figure 6: Installing the Face Plate
Rev 1
3