Electrical connection

This cooker hood is supplied for
connection to an AC 230 V ~ 50 Hz
supply. It must be connected to an
earthed socket which complies with
relevant regulations.
The electrical installation must comply
with VDE 0100 requirements (BS 7671
in the UK).
For increased safety you should protect
the appliance with a suitable Residual
Current Device (RCD) with a current trip
of 30 mA.
It is recommended that you connect the
appliance via a suitable socket . The
socket should be easily accessible after
the appliance has been installed.
If the socket is no longer accessible
after installation, an additional means of
disconnection must be provided for all
poles. Suitable means of disconnection
include switches with an all-pole
contact gap of at least 3 mm.
These include miniature circuit
breakers, fuses and contactors
(EN 60335).
The relevant connection data can be
found on the data plate (see "After
Sales/Warranty"). Ensure that this data
matches the voltage and frequency of
your household power supply.