Electrical C onnection
Thefour-wire connection i s preferred, butwherelocal c odes permit, t hethreewire
connection i s alsoacceptable.
Four-wireConnection
Junction
box
Cable from
_
power
supply
White wires
Ungrounded
Neutral
Black wires
Bare or green wires
Cable
from oven
U.L.-listed
conduit connector
Connect the red oven wire to the red electrical supply wire (hot wire).
Connect the black oven wire to the black electrical supply wire (hot wire).
Connect the white neutral oven wire to the white neutral (not bare ground)
electrical supply wire.
Connect the bare ground oven wire to the bare ground electrical supply wire.
Three-wire
Connection
Red wires_
_
Grounded Neutral
White wires
or green
_
. .-
innecto
rres
Bare
from oven
Connect red wire from oven to red wire injunction box.
Connect black wire from oven to black wire in junction box.
Connect both green ground wire and white wire from oven to white (or gray)
neutral wire in junction box.
The conduit cable, where connected at the oven, swivels. Rotate conduit cable
upward (or downward) and direct through hole prepared in cabinet to attach to J-
Box.
To maintain serviceability, the flex conduit must not be shortened and should be
routed to permit temporary removal of the oven.