Fitting Upper Clamps; Fitting Base Bracket And Lower Clamps - Bosch TSS Series Installation And Maintenance Instructions Manual

Thermosiphon system, flat roof installation
Table of Contents

Advertisement

1. Slide up angle profiles.
2. Screw angle profiles to the assembly stand.
2.
1.
0010016140-01
Fig. 37 Fastening connected angle profiles to the assembly stand
7.3

Fitting upper clamps

Only slightly tighten the screw connections, so that the collector can still
be installed.
▶ When there is one collector, screw clamps directly onto the assembly
stand using an oval head screw ( arrow).
Fig. 38 MTSS1: Screw clamps directly onto the assembly stand
TSS – 6720887696 (2018/05)
▶ When there are two collectors, fit clamps to the angle profile using an
oval head screw ( arrow).
0010016141-01
Fig. 39 MTSS2: Screwing clamps onto angle profiles
7.4

Fitting base bracket and lower clamps

▶ Fit the base bracket so that
– the collector sits at the bottom of the base bracket profile [1] and
– the clamp grips the side of the collector edge [2].
▶ Tighten all screw connections (corresponds to approx. 15 Nm).
2 x
0010016152-01
Fig. 40 Fitting the base bracket
Installing the MTSS flat roof frame
4 x
2
1
0010016142-02
17