DO NOT use this product to perform a task for which it is not designed.
DO NOT deface the certification plate attached to the end of the compressor tank.
DO NOT cover the compressor or restrict air flow around the machine whilst operating.
DANGER! DO NOT direct the output jet of air towards people or animals.
s
s
DO NOT operate the compressor without an air filter.
DO NOT allow anyone to operate the compressor unless they have received full instructions.
p WARNING! The air tank is a pressure vessel and the following safety measures apply:
DO NOT tamper with the safety valve and DO NOT modify or alter the tank in any way and DO NOT strap anything to the tank.
DO NOT subject the tank to impact, vibration or to heat and DO NOT allow contact with abrasive or corrosive materials.
DO drain condensation from tank daily and inspect inside walls for corrosion every three months. Have a detailed tank inspection
carried out annually.
The tank shell must not fall below the certified thickness at any point..
WARNING! If an electrical fuse blows, ensure that it is replaced with one of identical type and rating.
p
p
When not in use, disconnect from the mains, vent the tank and store the compressor in a safe, dry, childproof location.
2.
INTRODUCTION & SPECIFICATION
The SA2225/1.5.V2 Direct Drive Compressor has a single cylinder pump powered by a 230V 1ph motor and is capable of supplying air at up to 8
bar from a 25 litre tank. In addition to pneumatic tools, the compressor may be connected to accessories suitable for blowing, washing and
spraying. Two rear wheels and a handle provide ease of movement.
2.1.
Specification
Motor
Voltage/
Output
Model
Phase
(hp)
SA2225/1.5.V2
1.5
* Note: 2.5 bar is recommended pressure setting for spraying
6.0 bar is recommended pressure setting for air tools
2.2.
Weight & Dimensions
Weight
Model
(kg)
SA2225/1.5.V2
28
3.
PREPARATION
WARNING! The compressor is supplied without any lubricating oil in
p
the pump - see para. 3.5.
p
3.1.
Remove compressor from packaging and inspect for any shortages or damage.
If anything is found to be missing or damaged contact your supplier.
3.2.
Save the packing material for future transportation of the compressor.
We recommend that you store the packing in a safe location, at least for the period of the guarantee. Then, if necessary, it will be
easier to send the compressor to the service centre.
3.3.
Confirm that the mains voltage corresponds with the voltage shown on the compressor data plate.
3.4.
The compressor should be installed on a flat surface, or one that does not exceed 15
should be in a position that allows good air circulation around the unit.
3.5.
IMPORTANT! Remove the oil filler/breather from the pump and add the oil provided until the level is up to the centre of sight
glass (fig. 2). Replace the filler/breather. DO NOT attempt to run the compressor until this has been done.
3.6.
Screw air filter (fig.3.A) into inlet port.
Current
Pump
(A)
Type
Single
230/1
7
Cylinder
Dimensions
Length x Width x Height (mm)
645 x 350 x 590
fig. 1
Pump
Piston
Speed
Displacement
(rpm)
(cfm)
Max.
2958
7.3
fig. 2
Free Air Delivery
(cfm)
Capacity
At
At
2.5 Bar*
6.0 Bar*
5.8
5.5
4.9
All performance figures are ± 5%
either transversely or longitudinally (fig.1), and
O
Noise
Tank
Max.
Level
Pressure
Pressure/
(l)
(psi/bar)
Power
(dB.A)
25
116/8
92
fig. 3
SA2225/1.5.V2 - 1 - 010205