ODSHR Outdoor Woodburning Fireplace PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Safety Information .
3. Stainless steel cleaner available at hardware stores Regardless of which method is used, remember that any- thing with too much abrasive may dull the finish. Standard for Factory Built Fireplaces Unit: GH3SR0 Drafts Gas Logs Cleaning ODSHR42 Listed UL / ULc127...
Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation or exterior installation . Interior Chase Installation Batt Insulation (cut out around firestop) Firestop Ceiling Level Gas Line Access (both sides) Outside Air Cover Plate FP554A Fig.
Illustration Key The following safety rules apply to offset installations (letters correspond with illustra- tion above): A. Height of the chimney is measured from the hearth to the chimney exit. ODSHR42 Maximum: 90' (27.4 m) Minimum: Without Elbows 14'6" (4.4 m) With 2 Elbows* 15'6"...
Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting the Fireplace A fireplace may only be mounted on the following sur- faces: 1.
ODSHR Outdoor Woodburning Fireplace Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9 m) with 11CF chimneys. Locate chimney supports at ceiling holes or other structural framing at 30 foot heights.
Framing Framing can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2 or 3 for basic fireplace specifications.
ODSHR Outdoor Woodburning Fireplace Cutting the Hole Cover fireplace collar opening and cut proper sized chimney hole in chimney. Framing the Ceiling Hole Frame the ceiling chimney hole as shown in Figure 13. It is good practice to use framing lumber that is the same size as the ceiling joists;...
Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1¹⁄₂" (38 mm), allowing the remainder to extend in front of firebox. Overlap strips at least 1/2" (13 mm) to provide a posi- tive joint.
ODSHR Outdoor Woodburning Fireplace Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 17. When you get a good lock, you will hear the pipe clearly snap together.
Firestop spacers are not available for, nor are they required on, vertical walls. The CFM Corporation chimney components have been tested and approved with the area where the outer pipe slides through the firestop spacer sealed with a noncombustible caulk if desired, or left completely open with no sealant.
Page 14
ODSHR Outdoor Woodburning Fireplace Air Space Clearances Combustible framing material MUST NOT pen- etrate AIR SPACE (shaded areas) 2" Standoff ³⁄₄" Air Space to Sides Front View Wall Shield Only noncombustible mate- rial may be applied as facing to the fireplace surround. Fig.
Page 15
Mantel Clearance - No Noncombustible Facing Material 12" Combustible Mantel (305mm) and Trim Max. 1¹⁄₂" 12" (305mm) min. * Minimum width from top of sur- round to bottom of screen rail Ledge Bracket Fig. 24 Mantel clearances. 1���" Ref. * 12" (305 mm) from top of fireplace opening. ** 6"...
ODSHR Outdoor Woodburning Fireplace Side Wall Protection Adjacent combustible side walls that are within dimen- sions shown in Figure 25 of fireplace opening must be protected with CFM Corporation Wall Shield Model SP40 or a specifically built wall shield described in Figure 26.
Page 17
Alternate noncombustible materials may be used pro- viding the (total) thermal resistance (Rt value) of the al- ternate material employed is greater than or equal to R = 1.09. Thermal resistance (R) or thermal conductivity (K), may be obtained from manufacturer of the material. Factors are related by the formula K = 1/R.
ODSHR Outdoor Woodburning Fireplace Wall Covering Noncombustible Decorative Facing Seal All Cracks Between Fireplace Surround and Wall Materials with Noncombustible Material Noncombustible Decorative Cover- Hearth Extension Seal Crack Between Fire- Majestic Safety Strips place and Hearth Exten- Must be Overlapped 1/2" sion with Noncombustible Min.
CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. ODSHR Outdoor Woodburning Fireplace Ref. Description Damper Blade Damper Handle Screen Rail Screen Rod Screen (two per fireplace) Screen Pull (two per fireplace) Push Nut (two per fireplace) Firebrick - Back...
ODSHR Outdoor Woodburning Fireplace The following accessories for this appliance are available from your local CFM Corporation products distributor. Should you need additional information beyond what your distributor can furnish, contact: CFM Corporation, 2695 Meadowvale Blvd., Mississauga, Ontario, Canada L5N 8A3, Attn: Technical Services. CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be oper- ated only with CFM Corporation approved components.
Page 21
Accessory Extended Round Top Chimney Sections Chimney Elbows Top Housing with Upper Baffle Chimney Reducer Kit Attic Insulation Shield Contact the CFM Corporation with questions con- cerning prices and policies covering replacement parts. Parts may be ordered through your CFM Corporation distributor or dealer.
LIMITED WARRANTY & 30 YEAR PROTECTION PLAN For Majestic Fireplaces PRE-ENGINEERED Fireplace Systems CFM Corporation warrants its Pre-Engineered Fireplace (“Fireplace”) and the CFM Corporation-supplied firegrate, glass doors, outside air system, fan motor, and liners to be free from defects in material or workmanship, as follows: A.
Need help?
Do you have a question about the ODSHR42 and is the answer not in the manual?
Questions and answers