* If you cannot reach your gas supplier call the re department INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER Top Vent Direct Vent Models DBT33 DBT36 DBT39 & H OMEOWNER FOR YOUR SAFETY DO NOT STORE...
Replacement Parts Part Number List...26 Parts Pictorial ...28 Optional Accessories EB-1 Electrical Junction Box ...29 Fan Kits...29 Ceramic Refractory Lining ...31 Window Screen Kit...31 Decorative Bay Window ...32 Remote Control Units ...32 Warranty Imformation...Back Cover DBT33/DBT36/DBT39 ABLE ONTENTS warranty. 10002789/0...
6" (153 mm) clearance must be maintained from the perpendicular wall and the front of the appliance. See (Y) in Fig. 1. IMPORTANT: IREPLACE Fig. 1 B - Cross Corner D - ** Room Divider F - Chase Installation DBT33/DBT36/DBT39...
Ref. 1264 mm (49.75") DBT33/DBT36/DBT39 PPLIANCE IMENSIONS Appliance Dimensions DBT33 DBT36 838 mm (33") 914 mm (36") 733 mm (28.87") 870 mm (34.25") 416 mm (16.37") 533 mm (21") 787 mm (31") 838 mm (33") 559 mm (22") 610 mm (24") 356 mm (14")
Screw through the slotted holes in the drywall strip and into the pre-drilled holes in the replace side. Measure from the face of the replace to the face of the drywall strip to conrm the nal depth. Fig. 2 EARTH INISHING DBT33/DBT36/DBT39...
If a Trim Kit is going to be installed on the replace, the brick or tile will have to be installed ush with the edges of the appliance. DBT33/DBT36/DBT39 DBT33 / DBT36 / DBT39 CERTIFIED TO ANSI Z21.88b-1999 / CSA Z2.33b-M99 Vented Gas Fireplace Heaters...
ATURAL ATURAL AS TO The DBT33 is convertible between Natural Gas an LP gas (and vice-versa) with the use of a conversion kit purchased seperately, see your dealer for the correct part number. The DBT36 & 39 can only be converted from Propane to Natural gas.
(305mm) minimum ‡] N = Clearance above a roof shall extend a minimum of 24" (610mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18" (450mm). OCATION DBT33/DBT36/DBT39...
14' (4.3 m). EXAMPLE B: If the vertical dimension from the oor of the re place is 7' (214cm), the horizontal run to the face of the outer wall must not exceed 8-1/2' (2.6 m). (See Fig. 19). DBT33/DBT36/DBT39 RAPH...
The maximum number of 90º elbows per side wall instal- lation is three (3). • If a 90º elbow is tted directly onto the replace ange the maximum horizontal vent run before the termination is 36" (914 mm). DBT33/DBT36/DBT39 • PPLICATIONS • • •...
2" (50 mm)(or the distance required if installing a second 90º elbow. (Fig. 25). Always install horizontal venting on a level plane. Fig. 23 -13- Fig. 24 Fig. 25 DBT33/DBT36/DBT39...
4" vent pipe however for this method you must extend the 4" pipe approximately 6" (150 mm) beyond the outer face of the wall. DBT33/DBT36/DBT39 Support horizontal pipes every 3' (91 cm) with metal pipe straps. Check replace to make sure it is levelled and properly positioned.
Two sets of 45º elbow offsets within these vertical instal- lations. From 0 to a maximum of 8' of vent pipe can be used between elbows. (Fig. 31) -15- HROUGH PPLICATIONS Fig. 30 45º elbows = 10' 45º elbow = 8.5' 45º elbows = 7' DBT33/DBT36/DBT39...
Page 16
2'. See Fig. 38. ERTICAL ESTRICTOR (DBT33 ONLY When installing the DBT33 with a Vertical Through-The-Roof congured ue system the restrictor plate, (#10002495) sup- plied with the appliance MUST BE FITTED TO THE APPLIANCE at installation. Fitting The Restrictor Plate 1.
If an attic is above ceiling level a 7DVAIS (Attic Insulation Shield) must be installed. The enlarged ends of the vent section always face downward, Fig. 37. DBT33/DBT36/DBT39 Fig. 37 Fig. 38...
RIMPED DBT33/DBT36/DBT39 ENTING OMPONENTS Starter Kit -Model 7DVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDVSKV-F order at roof...
Model 7TDVP36" Model 7TDVP48" Firestop Spacer Model 7DVFS Attic Insulation Shield Model 7DVAIS Vertical/Horizontal Combination Offset Support Model 7DVCS 7DVSS Siding Shield (to protect siding) -19- for Below Grade Installation 12" to 18" adjustable length 35" to 64" adjustable length DBT33/DBT36/DBT39...
The top louvre panel is removed by lifting the panel vertically and pulling it away from the appliance, Fig. 39. The lower access door is hinged along the bottom edge and is folded down to allow access. DBT33/DBT36/DBT39 ENERAL PERATING It is necessary to periodically clean the glass.
9. Scatter the lava rock material around the rebox base. Do not place any of the lava rock material on the burner housing. Log Identication Chart Location DBT33 DBT36 Front left Front right Rear Top left Top right...
RN/RP & EN/EP Models For units equipped with ‘HI/LO’ valves the ame adjustment is accomplished by rotating the ‘HI/LO’ adjustment knob located near the centre of the gas control valve, Fig. 44 & 45 DBT33 Fig. 47 Fig. 44 Fig. 45 DBT36 Fig.
"OFF" and call your service technician or gas supplier. "ON" position or set thermostat to desired setting. Open control access panel. Push in gas control knob slightly and turn clock- wise to "OFF". Do not force. Close control access panel. DBT33/DBT36/DBT39...
TROUBLE SHOOTING THE GAS CONTROL SYSTEM HONEYWELL MILLIVOLT VALVE DBT33/DBT36/DBT39 -24- 10002789/0...
Page 25
100 mV. If the reading is okay and the burner does not come on, replace the gas valve. Clean and/or adjust pilot ame for maximum ame impingement on thermopile and thermocouple. Check the vent terminal for blockage (recycling the ue gases) -25- CORRECTIVE ACTION DBT33/DBT36/DBT39...
14b Gas Valve SIT820 RP Gas Valve Honeywell RN 15b Gas Valve, Honeywell RP Fan assembly (with bracket) (FK24 option) Electrical cord, (FK24 option). Fan temperature sensor, (FK24 option) Fan speed control, (FK24 option) DBT33/DBT36/DBT39 EPLACEMENT ARTS DBT33 10000470 10000023 10001454...
replace Install the thermal sensor under the bottom of the rebox, locating it over the two 10 mm studs and secure it with nuts. -29- VAILABLE DBT33/DBT36/DBT39...
Page 30
3. Power to the fan can be supplied by plugging the supplied lead into a conveniently located wall socket or by using a hard-wired EB1 connector box. DBT33/DBT36/DBT39 IRING The replace, when installed, must be electri- cally connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian...
ERAMIC EFRACTORY Ceramic refractory panels are available in kit form for the DBT series appliances. Appliance Model Kit Name DBT33 33BDVTCR DBT36 36BDVCR DBT39 39BDVCR Take care when handling the refractory panels as they are fragile until held in place and sup- ported.
ECORATIVE Bay window kits are available for the DBT33, DBT36 & DBT39 model appliances. When tting the Bay Window Kits the original front frame/glass assembly MUST remain in place. The Bay Window kit is tted over the existing front glass.
Page 34
1) Contact your supplier. Make sure you have your warranty, your sales receipt, and the model/serial number of your CFM Majestic, Inc. product. 2) DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF. DBT33/DBT36/DBT39 For Gas Appliance Products* GARANTIE DE BASE: The CFM Majestic.