en | Connections
3.3.1

12 V mode operation

Notice!
Make sure that the power supply has the correct output voltage
(12 V).
B7a
Figure 3.3: 12 V mode with one battery (left); 12 V mode with two batteries
(right)
12 V mode operation using one battery
1.
2.
3.
4.
5.
6.
2020-07 | V04 | F.01U.330.018
B12
B7b
+
-
Set the switch of the power supply unit to 12 V.
Connect B12 to the power supply interface labeled BAT.
Connect B7b (black) to the rechargeable negative (-)
terminal of the battery.
Connect B7a (red) to the rechargeable positive (+) terminal
of the battery.
Attach the bracket to the back of the housing next to the
batteries.
Attach the connectors B8a and B8b to the bracket.
B8a
B7a
B8b