Installation and Operating
Instructions for Unvented
Gas Log Heaters
Thermstatically Controlled Double Burner
Models:
UC181N, UE181N, UC241N, UE241N (Natural Gas)
UC181L, UE181L, UC241L, UE241L (Propane)
Decorative Gas Appliance For Installation In Solid Fuel Burning Fireplaces
If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fire department.
WARNING
This appliance is for installation in a a solid fuel
burning fireplace or approved ventless enclo-
sure. Do not install this appliance in bedrooms,
bathrooms, mobile homes or recreational
vehicles.
ATTENTION
This is an unvented gas fired heater. It sues air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and venti-
lation air must be provided.
Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot,
creosote, ashes and loose paint by a qualified chimney cleaner.
WARNING
Installation, service, and repair of this appli-
ance must be performed by a qualified
installer, service agency, company or gas
supplier experienced with this type of gas
appliance.
INSTALLER:
Read these instructions completely and care-
fully prior to beginning installation. The installer
should initiate the startup procedure and oper-
ate the gas log heater for a minimum of 15-30
minute test burn. After installation, leave these
instructions with the owner.
OWNER:
Read these instructions and follow the warn-
ings. Save this manual for future reference.
Keep appliance clear and free from combustible
materials, gasoline and other flammable vapors
and liquids.
Any changes to this heater or its controls can be
dangerous.
WARNING
CFM Home Products
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3
800-668-5323
Certified to ANSI Z21.11.2A Standard
ATTENTION
WARNING
WARNING
3311243 7/04 Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for CFM UC181L

  • Page 1 Thermstatically Controlled Double Burner Models: UC181N, UE181N, UC241N, UE241N (Natural Gas) UC181L, UE181L, UC241L, UE241L (Propane) Decorative Gas Appliance For Installation In Solid Fuel Burning Fireplaces If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Technical Information

    This unvented gas log heater has been certified by CSA and tested to conform to ANSI Z21.11.2 Gas Fired Room Heaters. Check local codes before installing this log heater. In some areas of the country, unvented gas log heaters are restricted. The installation and provision for combustion and ventilation air must conform with the National Fuel Gas Code, ANSIZ223.1/NFPA 54 (latest edition), the National Electrical Code, ANSI/NFPA 70 (latest edition) and any applicable local codes.
  • Page 3 CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air, vent free gas logs may give off carbon monoxide, an odorless, poisonous gas. Some people such as pregnant women, people with heart or lung disease and persons at high altitudes are more affected by carbon monoxide than others.
  • Page 4 Provisions for Adequate Combustion and Ventilation Air This heater shall not be installed in a “ CONFINED SPACE” or unusually tight construction unless provi- sions are provided for adequate combustion and ventilation air. The NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54 defines a “CONFINED SPACE” as a space whose volume is less than 50 cubic feet per 1000 BTU per hour (4.8m rating of all appliances installed in that space, and an “UNCONFINED SPACE”...
  • Page 5 The fireplace must meet the minimum dimensions listed below. (Fig. 1) Do not install the logset if the fireplace does not meet these minimums. Logset 18” - UC181N 18” - UE181N 24” - UC241N Natural 24” - UE241N 18” - UC181L 18” - UE181L 24” - UC241L Propane 24” - UE241L Fig. 1 Minimum fireplace dimensions. Ceiling 42"...
  • Page 6: Hood Installation

    ATTENTION: This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic flames. This heater is designed for vent-free operation with flue damper closed. State and local codes in some areas prohibit the use of vent-free heaters.
  • Page 7 • If the fireplace has glass doors, remove the glass doors and frame assembly or the upper door track. • If the upper door track has been removed, follow the instructions for Figure 3. If the upper door track remains, skip Figure 3 and follow the instructions for Figure 4.
  • Page 8: For Your Safety Read Before Lighting

    Connection to Gas Supply 1. Place the burner assembly (grate and control package) in the fireplace. Center the assembly front to back and side to side. 2. Install the gas supply fitting to the gas supply pipe. Use pipe thread sealing compound, or Teflon tape, on the iron pipe threads only.
  • Page 9 Guidelines After your installer does the test burn, the log set should be operated either with the chimney open or, in the absence of a chimney, with a window open approxi- mately 1-2 inches. This operation should last for about 2-3 hours to cure the logs and dissipate any residual fumes from the new unit.
  • Page 10: Thermostatic Control

    Thermostatic Control The thermostat control knob can be set to any comfort level between “HI” and “LO”. The thermostat will gradually modulate the heat output and flame height from higher to lower settings in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
  • Page 11: Oxygen Depletion System

    Oxygen Depletion System For your safety, this appliance is equipped with an oxygen depletion system. This system senses the oxygen in the firebox and switches off the gas supply before the amount of oxygen falls below safe levels. (Fig. 12) To clean the burner and pilot assembly: •...
  • Page 12 CFM Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. UC/UE181, UC/UE241 Series Unvented Gas Log Heaters Ref. Description Log Assembly - 2 Larger Bottom Logs Log Åssembly - 3 Smaller Top Logs Bag of Lava Rock (2 lbs.) (2 per Heater) Flexline Gas Connector...
  • Page 13: Warranty

    Lifetime Limited Warranty on logs in original fireplace only: One Year Limited Warranty on all other components in original fireplace only: If, during their lifetime, the cement logs fail due to a defect in material or workmanship, CFM Home Prod- ucts will repair or replace, at our option, free of charge.
  • Page 14 CFM Home Products 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323...

This manual is also suitable for:

Uc241nUc181nUe181lUc241lUe181nUe241l ... Show all

Table of Contents