Chapter 4 Securing The Chassis; Preparing The Rack For Chassis Installation - Cisco NCS 4000 Series Unpacking, Moving, And Securing Manual

Network convergence system
Hide thumbs Also See for NCS 4000 Series:
Table of Contents

Advertisement

Securing the Chassis
This chapter describes how to secure the Cisco NCS 4016 chassis in the rack.
To install two Cisco NCS 4016 chassis in a single rack, you will need to have a minimum vertical
Note
opening of 48 RU. If you are using the DC Power Front Connection Adapter, only one chassis will fit
into the rack.

Preparing the Rack for Chassis Installation

Install the Cisco NCS 4016 chassis into one of the following standard racks:
Note
For the ANSI 19-inch rack, the minimum front opening must be 17.72 inches (450 mm) to allow for
chassis insertion.
If you are installing a single chassis in a rack, the chassis must go in the middle or bottom portion of the
rack or follow your company chassis mounting practices.
At the bottom of the rack, keep 1 rack unit free to allow for removal of the bottom fan tray.
Note
To bolt the rack to the floor, a floor bolt kit (also called an anchor embedment kit) is required. For
information on bolting the rack to the floor, consult a company that specializes in floor mounting kits
(such as Hilti; see Hilti.com for details). Make sure that floor mounting bolts are accessible, especially
if annual re-torquing of bolts is required.
Preparing the Rack for Chassis Installation, page 4-1
Preparing to Mount the Chassis in a Rack, page 4-3
Mounting the Chassis into a Rack, page 4-12
Unpacking Chassis Component Shipping Pallets, page 4-16
ANSI 19-inch or 23-inch (2- or 4-post)
ETSI
Cisco Network Convergence System 4000 Series Unpacking, Moving, and Securing Guide
4
C H A P T E R
4-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncs 4016

Table of Contents