OWNER'S MANUAL & WARRANTY INFORMATION
12 VOLT 2/1 0/20/40 AMPERE CHARGE RATES WITH 1 00 AMP ENGINE START,
ALTERNATOR VOLTAGE CHECK AND BATTERY RECONDITON FUNCTIONS
• IMPORTANT SAFETY INSTRUCTIONS •
WARNING – RISK OF EXPLOSIVE GASES
1. WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES
GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS
REASON, IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR
CHARGER, YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY.
2. To reduce risk of battery explosion, follow these instructions and those published by the battery
manufacturer and manufacturer of any equipment you intend to use in vicinity of battery. Review
cautionary markings on these products and on engine.
GENERAL BATTERY SAFETY
1. Use charger for charging a LEAD-ACID battery only. It is not intended to supply power to a low volt-
age electrical system other than in automotive applications. Do not use battery charger for other types
of batteries, these may burst and cause injury to persons and damage to property.
2. Use of an attachment not recommended or sold by the battery charger manufacturer may result in a
risk of fire, electric shock, or injury to persons.
3. To reduce risk of damage to electric plug and cord, pull by plug rather than cord when
disconnecting charger.
4. An extension cord should not be used unless absolutely necessary. Use of an improper extension cord
could result in a risk of fire and electric shock. If extension cord must be used, make sure:
a. That pins on plug of extension cord are the same number, size, and shape as those of
plug on charger.
b. That extension cord is properly wired and in good electrical condition; and
c. That wire size is AWG #10 (10 gauge) to 100 feet and AWG #8 for distances over 100 feet.
5. Do not operate charger with damaged cord or plug - replace the cord or plug immediately.
6. Do not operate charger if it has received a sharp blow, been dropped, or otherwise damaged in any
way; take it to a qualified service technician.
7. Do not disassemble charger; take it to a qualified service technician when service or repair is
required. Incorrect reassembly may result in a risk of electric shock or fire.
8. To reduce risk of electric shock, unplug charger from outlet before attempting any maintenance or
cleaning. Turning off controls will not reduce this risk.
9. Do not expose charger to rain or snow.
10. Never charge a frozen battery.
SAVE THESE INSTRUCTIONS:
This manual contains important safety and operating instructions for battery charger Model VEC093
4140 SW 28TH WAY, FT. LAUDERDALE, FL 33312 • TEL: 954-584-4448 • FAX: 954-584-5556 • TOLL-FREE 866-584-5504
AUTOMATIC

BATTERY CHARGER

1
VEC093
A062003

Advertisement

Table of Contents
loading

Summary of Contents for Vector A062003

  • Page 1: Battery Charger

    10. Never charge a frozen battery. SAVE THESE INSTRUCTIONS: This manual contains important safety and operating instructions for battery charger Model VEC093 4140 SW 28TH WAY, FT. LAUDERDALE, FL 33312 • TEL: 954-584-4448 • FAX: 954-584-5556 • TOLL-FREE 866-584-5504 AUTOMATIC VEC093 A062003...
  • Page 2 USE OF AN ADAPTER IS NOT ALLOWED IN CANADA. IF A GROUNDING TYPE RECEPTACLE IS NOT AVAILABLE, DO NOT USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN. FIGURE 1B ADAPTER (B) GROUNDING MEANS METAL SCREW VEC093 A062003...
  • Page 3: Charger Location

    When disconnecting charger, disconnect AC cord, remove clip from vehicle chassis, and then remove clip from battery terminal. h. See operating instructions for length of charge information. i. Do not change the battery while the engine is operating. VEC093 A062003...
  • Page 4: Introduction And Features

    ATVs, trucks and various commercial applications. Vector Smart Chargers are microprocessor-based and have a charge curve that has three stages. See Figure 2. Stage One is essentially a constant current charge. This continues until the connected battery is about 85 percent charged.
  • Page 5: Controls And Indicators

    • THAT THE UNIT'S BUILT-IN CIRCUIT PROTECTION CAN NOT HANDLE. DO NOT OPEN THE UNIT. IT MUST BE RETURNED TO VECTOR FOR PROFESSIONAL TESTING AND REPAIR. • OPENING THE UNIT WILL VOID THE MANUFACTURER'S WARRANTY. Contact the Vector Technical Support Department at (954) 584-4446 or toll free at 866-584-5504 for further information.
  • Page 6 CHARGING COMPLETE - Indicates Battery is charged ALTERNATOR GOOD - lights when this particular load check shows the alternator is keeping up with the electrical load. in the upper left hand corner of the panel indicates many conditions. VEC093 A062003...
  • Page 7 NOTE: If there is any problem connecting the charger clamps to the battery terminals, contact the Vector Technical Support Department toll-free at (866) 584-5504 for assistance.
  • Page 8: 100A Engine Start

    If a battery remains in a discharged condition, the lead sulfate changes to a hard crystalline form, making a full charge difficult. BATTERY RECONDITION mode sends a sequence of electronic pulses into the battery, shaking loose and dissolving the crystals. VEC093 A062003...
  • Page 9: Care And Maintenance

    • Keep the charger cords loosely coiled during storage to prevent damage to the cords. Do not use the charger if cords or clamps have been damaged in any way - call Vector Technical Support Department toll-free at (866) 584-5504 for details on replacing cords and clamps.
  • Page 10: Troubleshooting - Fault Led Lit

    Try charging another battery, if the FAULT LED does not light, then one of the above problems exists. Charger will not charge and the fan will not operate if there is a fault. Call Vector Technical Support. SULFATED BATTERY (F03) When batteries are left in a discharged state for a long period of time, they become "sulfated".
  • Page 11: Appendix A - Charging Times

    Avoid high rate charging for stored batteries. PERCENT OF CHARGE PERCENT OF CHARGE NEEDED IN BATTERY 100% 12 HRS NR*** 3.0 HRS 4.5 HRS 1.5 HRS 3 HRS NR** NR** BY BATTERY 100% NR*** 6 HRS 3.5 HRS NR** VEC093 A062003...
  • Page 12 If such a product is returned more than 30 days but less than five year from the purchase date, Vector Manufacturing will repair the unit or, at its option, replace it free of charge.

This manual is also suitable for: