Removing Fuse F3

1� Remove the Fuse by opening the
fuse holder and pull the fuse out.
2� Remove the Fuse holder by
pushing it down and turning it
out�

Removing Relay K4

1� Remove the Relay by flipping the
plastic holder and pull the relay
out�
2� Remove the Relay Socket by
pushing it down and turning it
out�
Removing Phase
Sequencing Relay K3
1� Remove the Phase Sequencing
Relay by pulling down the lock
underneath with a screwdriver and
turn it out�
Removing Overload
Protection Q2
1� Remove the Overload Protection
Pkzmo by pulling down the lock
underneath with a screwdriver and
turn it out�