1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.5 Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
4.2 Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5
5.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6
6.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7
7.1 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machinery or plant.
The safety switchgear must be exclusively used in accordance with the
versions listed below or for the applications authorised by the manufac-
turer. Detailed information regarding the range of applications can be
found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all
prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is pro-
vided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant
components cannot be excluded. The relevant requirements
of the standard EN ISO 14119 must be observed.
EN
T.FH 232-..UEDR..
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TFH 232-11UEDR and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal TFH 232-11UEDR

  • Page 1 2.3 Destination and use ........2 Further technical information can be found in the Schmersal 2.4 Technical data .
  • Page 2 Operating instructions Safety foot switches T.FH 232-..UEDR.. 1.7 Exclusion of liability Design/Operating principle: overlapping contacts with pressure We shall accept no liability for damages and malfunctions resulting from de- point and latching (UEDR) fective mounting or failure to comply with this operating instructions manual. Representation Condition Function...
  • Page 3 Operating instructions Safety foot switches T.FH 232-..UEDR.. 2.4 Technical data 3. Mounting Standards: EN 60947-5-1, DIN VDE 0660-200, BG-GS-ET-15 3.1 Dimensions Material of the enclosure, All measurements in mm. cover and protective shield: aluminium Enclosure coating: powder-coated thermoplastic with 1 foot pedals Material of the pedal: glass-fibre reinforced thermoplastic Mechanical data...
  • Page 4 Operating instructions Safety foot switches T.FH 232-..UEDR.. 4.2 Contact variants 5. Set-up and maintenance The contacts are shown in a non-actuated condition. 5.1 Functional testing with 1 foot pedals The safety function of the safety components must be tested. The following conditions must be previously checked and met: 1 NO / 1 NC 2 NO / 2 NC...
  • Page 5 Person authorized for the compilation Oliver Wacker of the technical documentation: Möddinghofe 30 42279 Wuppertal Place and date of issue: Shanghai, November 10, 2014 Authorised signature Jianwei Xu Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net.
  • Page 6 Production site: SCHMERSAL 施迈赛工业开关制造(上海)有限公司 K.A. Schmersal GmbH & Co. KG Industrial Switchgear (Shanghai) Co., Ltd. Möddinghofe 30, D - 42279 Wuppertal Cao Ying Road 3336 地址:上海市青浦区漕盈路3336号 Postfach 24 02 63, D - 42232 Wuppertal 201712 Shanghai / Qingpu, P.R.CHINA 邮编:201712...

This manual is also suitable for:

Tfh 232-22uedrT2fh 232-11uedr/11uedrT2fh 232-22uedr/22uedrT2fh 232-11/22uedrT2fh 232-22uedr/11

Table of Contents