Universal 150-FASNG Owner's Manual

Forced air natural gas construction heater

Advertisement

FORCED AIR NATURAL GAS CONSTRUCTION HEATER
STOP
HEATER SPECIFICATIONS................................................................................................................ 2
WARNINGS .................................................................................................................................. 2
OPERATING PRECAUTIONS ............................................................................................................. 3
SAFETY PRECAUTIONS .................................................................................................................... 3
ODOR FADE WARNING ...................................................................................................................... 4
OPERATING INSTRUCTIONS ............................................................................................................ 5
SERVICING ......................................................................................................................................... 5
150-FASNG - PARTS ........................................................................................................................... 6
150-FASNG - WIRING DIAGRAM ........................................................................................................ 7
WARRANTY ......................................................................................................................................... 8
SERVICE CENTERS .......................................................................................................................... 8
INSTRUCTIONS FOR ORDERING PARTS ........................................................................................ 8
WARRANTY REGISTRATION ............................................................................................................. 9
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
OWNERS MANUAL
Model
150-FASNG
QUESTIONS?
MISSING / DAMAGED PARTS
Please do not return this product to the store.
If a part is damaged or missing, simply e-mail us at
php@allpro-heaters.com, or visit our website at
http://allpro-heaters.com, or call our Customer
Service Department at (888) 619-7060.
We will be happy to assist you!
You can register your heater on line at
http://allpro-heaters.com/warranty.

TABLE OF CONTENTS

© 2002 Scheu Products Company

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 150-FASNG and is the answer not in the manual?

Questions and answers

Summary of Contents for Universal 150-FASNG

  • Page 1: Table Of Contents

    ODOR FADE WARNING ... 4 OPERATING INSTRUCTIONS ... 5 SERVICING ... 5 150-FASNG - PARTS ... 6 150-FASNG - WIRING DIAGRAM ... 7 WARRANTY ... 8 SERVICE CENTERS ... 8 INSTRUCTIONS FOR ORDERING PARTS ... 8 WARRANTY REGISTRATION ... 9...
  • Page 2: Heater Specifications

    115V, 60 Hz, 1Ø, 3a Ignition: Direct Spark, interrupted type Primary Flame Control: Solid State, 10-15 Second Timing High Temperature Control: 240°F (116°C) Model: 150-FASNG Rating: 150,000 Btu/hr (43.93 kW) Fuel Consumption: 139 CuFt/HR Fuel Orifice Port No.: Fuel Orifice Port Size: 0.0595...
  • Page 3: Operating Precautions

    Forced air (3500-FACV, SPC-350) ... 3 ft Forced air (7000-FACV) ... 4 ft Model 150-FASNG 1. Check the heater thoroughly for damage. DO NOT operate a damaged heater. 2. DO NOT modify the heater or operate a heater which has been modified from its original condition.
  • Page 4: Odor Fade Warning

    (LP) gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system. Model 150-FASNG ODOR FADE WARNING heater dataplate, or contact the Scheu Products Company to determine combustion air ventilation requirements of the heater.
  • Page 5: Operating Instructions

    1. The heater should be inspected before each use, and at least annually by a qualified person. Model 150-FASNG SERVICING A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly: * The flame is contained within the heater.
  • Page 6: 150-Fasng Parts

    1036 Power Cord 6223 Bushing, Strain Relief 1171 Fuel Tube Ass'y 1939 Motor Shell 1561 Motor Ass'y 6074 Fan Blade 3132 Saddle, Motor Support 150-FASNG PARTS Qty. Item Part No. 7095 6146 6259 6125 3087 3037 7295 6010 3038 8682...
  • Page 7: Wiring Chart

    Black 1226 Red (Hi-Temp) 1226 Red (Hi-Temp) 1070 Orange 1959 Green 1959 1959 White 1959 Black MODEL 150-FASNG WIRING DIAGRAM WIRING CHART LENGTH FROM 7" Valve 6" On/Off Switch 16 1/2" High Limit Switch 16 1/2" High Limit Switch 11"...
  • Page 8: Limited Warranty

    There is no warranty against infringement of Model 150-FASNG the like and no implied warranty arising from course of dealing or usage of trade. This warranty will not apply to any product...
  • Page 9: Warranty Registration

    Other Warranty Serviceability Fuel economy Warehouse Ease of use Patio Size Fold Here S/N (Located on a silver label on heater) Universal City Warehouse Retailer Discount Store State Postal code $20,000 to $34,999 $20,000 to $34,999 50-59 years >60 years...
  • Page 10 SCHEU PRODUCTS COMPANY, INC ATTN: MARKETING DEPARTMENT 8855 BAKER AVENUE RANCHO CUCAMONGA, CA 91730 Visit our website for product information, technical support, customer service, and warranty registration at: WWW.ALLPRO-HEATERS.COM for All-Pro products or WWW.UNVERISAL-HEATERS.COM for Universal products.

Table of Contents

Save PDF