Unigreen Minibar Use And Maintenance Manual

Mounted mistblowers
Table of Contents

Advertisement

Quick Links

GB
USE AND MAINTENANCE MANUAL
®
MISTBLOWERS AIRDROP - MFC
MOUNTED MISTBLOWERS
serie AIRDROP P - ELETTRA P - MFC P:
Ventagli - Minibar - Super Spalliera - RV-GDC
Read this manual carefully before use.
04/2010

Advertisement

Table of Contents
loading

Summary of Contents for Unigreen Minibar

  • Page 1 USE AND MAINTENANCE MANUAL ® MISTBLOWERS AIRDROP - MFC MOUNTED MISTBLOWERS serie AIRDROP P - ELETTRA P - MFC P: Ventagli - Minibar - Super Spalliera - RV-GDC Read this manual carefully before use. 04/2010...
  • Page 2: Table Of Contents

    MULTIPLIER - FAN UNIT ... 17 CLUTCH ... 17 DISTRIBUTOR ACCESSORIES ... 18 5.3.1 VENTAGLI (FANS) CANOPY, AND ESPALIER DISTRIBUTORS ... 18 5.3.2 MINIBAR FOR ESPALIER ... 18 5.3.2 SUPER SPALLIERA FOR ESPALIER ... 18 5.3.3 RV BOOM FOR GDC ... 19 HYDRAULICS ... 19 5.4.1...
  • Page 3 TABLES FOR CALIBRATING AIRDROP 2 VENT. (FANS) ESPALIER TOPDIF. .. 26 TABLES FOR CALIBRATING AIRDROP 2 VENTAGLI (FANS) VR.ESPALIER ... 26 TABLES FOR CALIBRATING AIRDROP MINIBAR ... 27 TABLES FOR CALIBRATING AIRDROP RV-GDC ... 28 TABLES FOR CALIBRATING AIRDROP SUPER SPALLIERA ... 28 TABLE 3 TABLES OF DELIVERY CALIBRATED PLATE...
  • Page 4: Using And Keeping The Use And Maintenance Manual

    Improper use: The use the UNIGREEN machines are designed for is indicated in this manual, any other use is forbidden and makes the guarantee void. PRODUCT RESPONSIBILITY...
  • Page 5: Safety Regulations And Residual Risks

    It is obligatory to keep all the plates with danger and safety signs in perfect conditions. If they get damaged or deteriorate, replace them in good time. Replace parts believed to be faulty with others indicated by UNIGREEN. NEVER try makeshift or hazardous solutions.
  • Page 6: Intended Use

    The use of liquid fertilizers in suspension is not allowed, while the use of the same in a solution is possible if requested when the machine is ordered from Unigreen and in any case changing some of the parts described in the handbooks of the regulator, such as the manometer (stainless steel), the nozzles (large diameter ceramic) and eliminating the fine mesh filters to prevent blockages.
  • Page 7: Taking Precautions Against Fire Hazards

    Please contact the agent in your zone, the nearest authorised workshop or UNIGREEN S.p.A. directly for any repairs the user feels they aren’t capable of performing alone. (see point 8.4) Due to the complexity of the equipment and the variety of technologies used (mechanical, hydraulic, oil-pressure and electrotechnical) operators must not dismantle or modify the equipment.
  • Page 8: Noise Level Of The Machine

    The pumps are generally diaphragm pumps but in some cases they are fitted with pistons. The accessories for completing the fitting, non-drip jets and ceramic nozzles make the UNIGREEN mistblower a highly qualified and efficient piece of equipment. 4.1.1 WORK STATIONS The use of this machine does not envisage an operator standing constantly near the same, the operator normally sits in the cab of the tractor.
  • Page 9: Hand Washing Tanks

    When you receive the machine, check that it is complete and no parts are missing. If there are any damaged parts, inform your local reseller or UNIGREEN directly in good time. When the machine is delivered, make sure you ask: that the machine is delivered with all of its parts fitted and that the fitting meets the requisites in table N°...
  • Page 10: Tractor Coupling

    + operator (75kg) ballast mass sprayer mass 10 unigreen TRACTOR COUPLING The tractor must have 1”3/8 ASAE DIN 9611/A power-takeoff that runs at 550 rpm. It must have a 3-point elevator suitable for safely supporting the weight of the atomiser.
  • Page 11: Cardan Shaft

    After washing the cartridge, reassemble the cover making sure you connect the same to the circuit again, using the valves described above in the opposite order. WARNING!: Don’t disperse the washing residues in the environment!! FIG. 6 FIG. 7 FIG. 8 Valve Filter unigreen 11...
  • Page 12: Pressure Regulator

    If the tractor has a waterproof cabin the use of electrical controls is obligatory. 4.8.1 COMPONENTS OF THE PRESSURE REGULATOR Below you will find the indications for the main models fitted on Unigreen products. A main ON-OFF command: “open” lets the fluid flow into the circuit in use;...
  • Page 13: Delivery Filters (Only Equipped Models)

    The pressure is normally regulated to 30-35 bar with the relevant valve (using a yellow knob) and displayed on the manometer installed; opening the utilities makes the pressure drop. FIG. 9 Tank rinsing Ejector Agitator 1 Agitator 2 unigreen 13...
  • Page 14: Filling The Tank

    This reading is precise if the tank is on flat ground; the actual total capacity coincides with the highest number. All the filling systems fitted by Unigreen on their production machines or on request are antipollution and stop the liquid overflowing out of the tank.
  • Page 15: Mixing

    - Introduce the tin into the hopper, inserting the washing pipe into the tin. -Press the tin onto the pipe until it has been washed clean. -At the end of the operations close the tap (D) of the pressure regulator Box washing device on cover again. unigreen 15...
  • Page 16: Washing The Atomiser

    16 unigreen 4.13 WASHING THE ATOMISER After every treatment, thoroughly clean the equipment, washing it with water inside and out. Dirty equipment is very dangerous for people and in particular for children.
  • Page 17: Blower Group

    0.5 bar. Boxes designed to be used for particularly heavy duty work are equipped with a breather cap that can be fitted on any cast iron box on request. Ø500 Nylon impeller with sinterized expansion clutch. unigreen 17...
  • Page 18: Distributor Accessories

    Various configurations of accessories or distributors are fitted to the outlet of the fans. At present these are: 2 Fans, Canopy and Espalier - Double espalier Minibar - RV espalier and GDC - VL Espalier - FXF "Up and Over" boom for espalier.
  • Page 19: Rv Boom For Gdc

    Pay attention to the integrity and efficiency of the hydraulic components and in particular to the pipes to prevent the risk of bursting. Do a full check on the pipes and components at least once a year, we recommend replacing hydraulic pipes every 3-4 years. unigreen 19...
  • Page 20: Spraying

    (see paragraph 6.4.1) DESCRIPTION OF THE MFC The Unigreen low-volume pneumatic atomization system uses MFC nozzles (FIG. 19) consisting of a steel wire supported by Nylon deflector vanes that also act as collectors for the liquid. The high-speed action of the air atomises the film of liquid on the wire;...
  • Page 21: Batching Taps (See Picture 20)

    Example- In the table: 280 lt/ha with row distance 3m. 280x3 = 300 Lt/ha with row distance 2,8m FIG. 20 FIG. 21 ANTIDRIPPING VALVE MARKED SIDE GASKET CALIBRATED PLATE 4916-47 4916-51 4916-55 unigreen 21 4916-70...
  • Page 22: Calibrated Plates Cp

    We recommend using a table of programmed maintenance to follow in time to keep the mistblower in an efficient working condition. For major and important maintenance jobs we recommend using the normal UNIGREEN assistance service available from your reseller, (if necessary) replacing parts using original spare parts only. ROUTINE MAINTENANCE After every treatment wash the inside of the tank and the entire circuit as indicated in paragraph 4.13...
  • Page 23: Cleaning The Nozzles

    REPAIRS We recommend having the normal UNIGREEN assistance service available from our reseller perform any repairs or contact a specialised workshop. During all of the repairs, in particular when welding, the machine and the circuit must be clean of any residues of chemical product.
  • Page 24: Putting Back Into Service After Winter Layup

    The user of the present machine can contact the collection centres instituted by the Local Authorities or the UNIGREEN Company directly, or request withdrawal by the dealer, in order to carry out correct disposal of the waste.
  • Page 25: Tables For Calibrating Airdrop 2 Ventagli (Fans) Vr.canopy

    AIRDROP CALIBRATING TABLES TABLES FOR CALIBRATING AIRDROP 2 VENTAGLI (FANS) VR.CANOPY unigreen spa Tabella erogazione in Litri/ettaro per diffusori a ventaglio Vr. Tendone PRESSIONE bar Litri/min. 3.74 4.00 4.50 N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.4, page 25).
  • Page 26: Tables For Calibrating Airdrop 2 Vent. (Fans) Espalier Topdif

    TABLES FOR CALIBRATING AIRDROP 2 VENTAGLI (FANS) VR.ESPALIER unigreen spa Tabella erogazione in Litri/ettaro per diffusori a ventaglio Vr. Spalliera PRESSIONE bar Litri/min. 3.74 4.00 ATTENTION: the OPTIONAL tabel shows the spreading rate of the two top side diffusers only, which has always to be added to that one of the fans.
  • Page 27: Tables For Calibrating Airdrop Minibar

    TABLES FOR CALIBRATING AIRDROP MINIBAR Tabella erogazione in Litri/ettaro per MINIBAR spalliera (6 diffusori) unigreen spa PIASTRINA CALIBRATA 4916/40 PRESSIONE bar 276 313 362 395 456 504 536 572 539 597 646 692 892 990 1035 1107 241 274 317 346 399 441 469 501 472 523 565 606 780 866 905 969...
  • Page 28: Tables For Calibrating Airdrop Rv-Gdc

    TABLES FOR CALIBRATING AIRDROP SUPER SPALLIERA unigreen spa Tabella erogazione in Litri/ettaro per SUPER SPALLIERA (8 diffusori) Lt./ha spreading rate table - SUPER SPALLIERA (8 diffusors) PIASTRINA CALIBRATA 4916/40 PRESSIONE bar 368 417 483 527 608 671 715 763 719 797 861 923 1189 1320 1380 1476...
  • Page 29: Table 3 Tables Of Delivery Calibrated Plate

    14,1 16,4 8,50 10,2 12,9 14,0 10,8 13,4 16,8 19,1 9,20 10,9 13,7 14,5 11,7 14,3 17,9 21,0 10,5 12,5 14,9 16,4 12,7 15,8 19,7 23,0 Ø 3,0 11,5 18,4 14,4 24,1 18,0 28,2 18,8 30,1 20,9 33,0 unigreen 29...
  • Page 30: Table 7 Table Of Programmed Maintenance

    Noisiness and the level of the oil has dropped Water in the oil No liquid comes out of the nozzles NOTE: ( * ) Only specialised technician 30 unigreen CAUSES Air suction Adjustment valve closed (Command group isn’t at zero pressure)
  • Page 31: Tab.18A Allowed Fittings

    " " " " PRESSURE GCP 2 ELECTRIC REGULATOR GCP 2 ELECTRIC +PRES NOZZLES DISTRIBUTOR 2 VENTAGLI ACCESSORIES MINIBAR SUPER SPALLIERA RV GDC OPTIONAL TOP DISTR for VENTAGLI MIXER LP83 COMPUTER TOTAL MASS EMPTY MAX FITINGS in Kg FULL MAX FITINGS...
  • Page 32 Rinaldi, 105 - 42124 Reggio Emilia - ITALY Tel. +39 0522 369811 Fax. +39 0522 369898 e-mail: info@unigreen-spa.com internet: www.unigreen-spa.com member of the group Descriptions, indicative illustrations, UNIGREEN S.P.A. reserves the right to make variations or modifications without prior warning.

Table of Contents