It will be the responsibility of the consignee to file a claim with the carrier. We recommend that you do so at once. Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing product unifiedbrands.net, for the most updated product information and...
In addition, all Avtec food service equipment is backed by some of the best warranties in the foodservice industry and by our professional staff of service technicians. Retain this manual for future reference. Due to a continuous program of product improvement, Avtec NOTICE: reserves the right to make changes in design and specifications without prior notice.
Installation Instructions This manual covers three of the basic types of systems offered by Avtec: TYPES OF SYSTEMS • TAKU-Baffle Filter (AF) • Modular Grease Extractor (AX) • Auto Wash Down (AW) BAFFLE FILTER (AF) SERIES Model AF ventilators are listed by UL and are built in accordance of NFPA-96 for use with UL listed re extinguishing systems for duct hood protection.
INSTALLATION REQUIREMENTS FOR ALL AVTEC TAKU VENTILATION HOODS CANOPIES Figure 1 Figure 2 HANGER BRACKET DETAIL HOOD ANGLE OF HOOD NOTE: HOLES DRILLED THROUGH HOOD ANGLE BY INSTALLER AFTER BRACKET ATTACHMENT POINTS HAVE BEEN DETERMINED. Installation Instructions Avtec hoods are provided with adjustable hanging brackets designed to receive 1/2” threaded rod with a 1/2”...
EXHAUST FAN & DUCT 888-994-7636 Installation Instructions 1. Check all local codes prior to installation. 2. All exhaust fans are supplied with a hinge kit and grease box. 3. The exhaust fan curb should be installed directly above the hood if possible. Always maintain the shortest duct run possible.
Control panels are provided with all auto wash type ventilators (Model AW) and are WALL ATTACHMENT optional with all baffle filter type (AF) and modular grease extractor type (AX). Control panels with models (AF) and (AX) do not have the auto wash plumbing assembly compartments.
FRESH AIR SUPPLY FAN CONTINUED (See Fig. 6) 888-994-7636 Installation Instructions Side Skirts Figure 5 10' - 0" MINIMUM GREASE TERMINATOR GREASE TROUGH PIECES PROVIDED One or two optional side skirts may be provided. 1. Side skirts are offset at the top and have a 90° bend inward at the rear. 2.
PIECES PROVIDED TOP ENCLOSURES INSTALLATION OF Enclosure panels are provided for exposed side(s) of hood(s). ENCLOSURE PANELS 1. Hoods ordered with enclosure panels will be shipped with threaded metal studs (See Fig. 7-9) installed on perimeter of hood top where panels are to be installed. Retaining nuts and washers are installed on the studs prior to shipping.
INSULATED WALL PANEL (See Fig. 10) SINGLE THICKNESS WALL PANEL (See Fig. 11) 888-994-7636 Installation Instructions Insulated Stainless Steel Wall Panels PIECES PROVIDED Insulated wall panel comes in two pieces. A. Top panel will have a 1” flange full length top and bottom with interlocking slots located on the bottom.
DIRECT DRAW HOODS 1. Close all doors and windows. 2. Operate all exhaust fans, even fans serving other hoods, make-up air units and building HVAC. 3. Turn on all cooking equipment under the hood to preheat to operating temperature. 4. Produce large quantities of smoke. 5.
6. If all vapors are not totally captured, ne tune the system by adjusting the air volume control damper installed in the supply collar. Slightly reduce the amount of supply air directed under the hood until full capture is obtained. UNIFIED BRANDS 888-994-7636 fax 888-864-7636 unifiedbrands.net...