  • Page 1 ThermoShaker Mixing Block MB-202 Type Oscillating Dry Bath Operation Manual...
  • Page 2 Caution: right to modify this manual at any time without notice. All rights reserved. Without prior written consent from Hangzhou Bioer Technology Co., Ltd., any part of the manual shall not be duplicated, reproduced or translated into any other languages.
  • Page 3 Hangzhou Bioer Technology Co., Ltd. would be irresponsible for any consequence resulted from the user’s failure to observe the following requirements.
  • Page 4 Operation Manual for Oscillating Dry Bath Important Notes must be replaced but not be repaired. The replacement shall be carried out with the power line of the same type and same specification. No goods shall be put on the power line when the instrument is working and please do not put it in a frequently-visited place.
  • Page 5 Maintained products shall be sent to maintenance department designated by Hangzhou Bioer Technology Co., Ltd. by the user. The freight incurred thereof shall be borne by the user. Hangzhou Bioer Technology Co., Ltd. will bear the freight incurred by returning instrument. (For domestic users only) For maintenance out of warranty period, Hangzhou Bioer Technology Co., Ltd.
  • Page 6: Table Of Contents

    Operation Manual for Oscillating Dry Bath Contents Contents CHAPTER I INTRODUCTION -------------------------------------------------------------------------------------- 1 CHAPTER II FEATURES --------------------------------------------------------------------------------------------- 2 1 NORMAL WORKING CONDITIONS --------------------------------------------------------------------------- 2 2 TRANSPORTATION AND STORAGE CONDITIONS ------------------------------------------------------- 2 3 BASIC PARAMETERS AND PERFORMANCE --------------------------------------------------------------- 2 CHAPTER III PREPARATORY WORK --------------------------------------------------------------------------- 4 1 STRUCTURE DIAGRAM ------------------------------------------------------------------------------------------- 4 CHAPTER IV OPERATION GUIDE ------------------------------------------------------------------------------- 5 EXAMINATION BEFORE STARTUP ------------------------------------------------------------------------------ 5...
  • Page 7: Chapter I Introduction

    Operation Manual for Oscillating Dry Bath Chapter I Introduction Chapter I Introduction This product is a dry bath adopting advanced microcomputer control, which can choose a variety of metal modules applicable to a variety of test tubes. It can be widely used in the preservation of samples, preservation and reaction of all kinds of enzymes, electrophoresis pre-degeneration, serum coagulation, incubation and culture of all kinds of molecular biological experiments with oscillation requirements, etc.
  • Page 8: Chapter Ii Features

    Operation Manual for Oscillating Dry Bath Chapter II Features Chapter II Features This chapter mainly introduces the usage, transportation and storage conditions of the instrument, as well as its basic parameters, performance and functions. 1 Normal Working Conditions Ambient temperature: 10C ~ 30C Relative humidity: ≤70% Power supply: AC220V22V 1.5A 50Hz1Hz Surface for placement: Horizontal, stable...
  • Page 9 Operation Manual for Oscillating Dry Bath Chapter II Features Model MB-202 Temperature setting 0~100℃ range Temperature control Room temperature -15° C to 100° C (minimum temperature 0° C) range Time setting 1min~99h59min Temperature 20℃-45℃≤±0.5℃ ; <20° C 或>45°C≤±0.8℃ fluctuation Temperature control ≤0.5℃(15℃~100℃)...
  • Page 10: Chapter Iii Preparatory Work

    Operation Manual for Oscillating Dry Bath Chapter III Preparatory Work Chapter III Preparatory Work This chapter mainly describes the structure, operating keyboard and function of each button of the instrument, as well as the preparatory work before the startup. When using this instrument for the first time, familiarize yourself with the content of this chapter before starting up.
  • Page 11: Chapter Iv Operation Guide

    Operation Manual for Oscillating Dry Bath Chapter IV Operation Guide Chapter IV Operation Guide This chapter describes in detail the method of temperature setting, oscillation time setting and oscillation speed setting of the oscillating dry bath, as well as how to correct the error between the actual temperature and the display temperature, and the setting of the buzzer.
  • Page 12 Operation Manual for Oscillating Dry Bath Chapter IV Operation Guide 1. Main interface After the instrument is powered on, turn on the power switch and the display will enter the main interface. The main interface includes Program, Single Point Set, System, Inching these four option buttons.
  • Page 13 Operation Manual for Oscillating Dry Bath Chapter IV Operation Guide Click "Delete" in the file list interface, and the deletion confirmation box will pop up; click "Yes" to confirm the deletion of the file and click "No" to cancel the deletion. After the operation is done, go back to the file list interface.
  • Page 14 Operation Manual for Oscillating Dry Bath Chapter IV Operation Guide In the section information editing interface, click on the option box behind the temperature to enter the temperature rise / drop and speed setting interface. Set the temperature rise / drop and speed with the 12 keys on the right. Click "OK"...
  • Page 15 Operation Manual for Oscillating Dry Bath Chapter IV Operation Guide will pop up. Select "Yes" to overwrite the existing file, select "No" to go back to the file saving interface, and finally save the file after modifying the file name. After the file is saved successfully, a prompt box saying “The file has been saved!”...
  • Page 16 Operation Manual for Oscillating Dry Bath Chapter IV Operation Guide 3. Single point set Different from a file, a single point has only one section. In the main interface, click "Single Point Set" to enter the single point setting interface. The operation is similar to that of the section information editing interface, and the difference is that because it has only one section, you can click "Run"...
  • Page 17 Operation Manual for Oscillating Dry Bath Chapter IV Operation Guide Click "Details" in the running interface to enter the running details interface. The details interface includes not only the running information of the current section, but also the entire running file information and the total run time.
  • Page 18 Operation Manual for Oscillating Dry Bath Chapter IV Operation Guide code 0x1 means short-circuit of the sensor; 0x2 means open-circuit of the sensor. If an alarm prompt tone is set in the system settings, the instrument will make a sound to indicate it when a fault occurs. Alarm Interface 8.
  • Page 19: Chapter V Fault Analysis And Troubleshooting

    Operation Manual for Oscillating Dry Bath Chapter V Fault Analysis and Troubleshooting Chapter V Fault Analysis and Troubleshooting This chapter mainly introduces the possible fault phenomena, causes analysis and troubleshooting of this instrument. Fault Analysis and Troubleshooting Serial Fault Phenomenon Cause Solution Remarks...
  • Page 20: Display Fault Alarm Message Prompt Comparison Table

    Operation Manual for Oscillating Dry Bath Chapter V Fault Analysis and Troubleshooting Check the power Crash phenomenon line to ensure good Poor grounding occurs at the time of grounding; replace replacing the module the module when instrument parts the power is turned off.
  • Page 21: Appendix 1: Mb-202 Wiring Diagram

    Appendix 1: MB-202 Wiring Diagram — —...