Download Print this page

Ultra Products ULT31502 Specification Sheet

Uninterrupted power supply (ups)

Advertisement

Quick Links

Uninterrupted
Power Supply (UPS)
The Ultimate Power Protection!
If you're looking for the most complete, technologically advanced power
protection unit for the money, the Ultra UPS line is exactly what you need. An
Ultra UPS is an absolute must for anyone running a small server, workstation or a
powerful PC. You simply cannot afford to cut corners when it comes to
safeguarding your valuable equipment, and these UPS's deliver the
comprehensive protection for computer, peripherals and data files at a
remarkably low price.
Features
- Line Interactive Design
- AVR (Automatic Voltage Regulation)
- Fully Digitized Microprocessor Controlled
- Protects up to 4 Devices at Once
- Energy Saving Function (UPS Green Mode)
- 50/60Hz Frequency Auto Sensing and Selection
- USB Communication Port
- Advanced Battery Management (ABM Technology)
1000VA
Gneral
Sku
ULT31502
Backup Time
About 50 Minutes
Net Weight Kg (lbs)
28.6(63.0)
Digital Display
Yes
Output
Watts
615
UPS Capacity
1025VA
No. of Sockets
Style A UPSx4, Bypassx2
Voltage (Battery)
Simulated square wave output at nominal +/-5%
Frequency (Battery)
50 or 60Hz +/- 0.3Hz
Transfer Time
2-4 milliseconds, including detection time
Input
Voltage (Single Phase)
120V +15%/-20% at line input
Frequency
50 or 60Hz +/- 10% (auto sensing)
Protection
Unit Input
Circuit breaker for overload & short circuit protection
Overload Protection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
Short Circuit
UPS output shuts off immediately
Surge Protection
2100 Joules
Battery
Type
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
Typical Recharge Time
6 hours (to 90% of full capacity)
Protection
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Interface
USB
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Alarm
Battery Backup
Slow beeping sound every 4 seconds
Battery Low
Rapid beeping sound every second
Abnormal Charge
AC Mode: Rapid beeping sound every 0.5 second
Overload
Continue beeping sound
Environment Ambient Operation
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30
Automatic Voltage Regulation (AVR)
Protect your computer from electrical damage caused
by dangerous "spikes and sags".

$125,000 Limited Warranty

Includes

UPS Monitoring

Software
1025VA
ULT33044
About 50 Minutes
28.6(63.0)
Yes
615
1025VA
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
UPS output shuts off immediately
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30
Includes
UPS Monitoring
Software
1500VA
ULT33045
About 60 Minutes
Yes
900
1500VA
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
UPS output shuts off immediately
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30
1-800-830-0051
www.ultraproducts.com
2000VA
ULT33046
About 65 Minutes
Yes
1200
2000VA
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
UPS output shuts off immediately
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30

Advertisement

loading

This manual is also suitable for:

Ult33044Ult33045Ult33046