Installation Location; Installing The Indoor Unit - Mitsubishi Electric Mr. Slim PCA-A-KA7 Series Installation Manual

Split-system heat pump
Hide thumbs Also See for Mr. Slim PCA-A-KA7 Series:
Table of Contents

Advertisement

Available languages

Available languages

2. Installation location

W
Fig. 2-1

3. Installing the indoor unit

Fig. 3-1
A
1/16
B
2-15/16
9-3/16
9-11/16
Fig. 3-2
7-1/2
3-1/8
Ø2-9/16
Fig. 3-3
(inch)
9-5/16
Min. 19-11/16
(inch)
9-5/16
1/16
3-3/8
3-3/8 1/16
5-7/16
7-1/16
7-7/8
9-3/16
9-11/16
2-3/4
6-5/16
4-15/16
Ø3-15/16
2.1. Outline dimensions (Indoor unit) (Fig. 2-1)
Select a proper position allowing the following clearances for installation and main-
tenance.
Models
W
A24, 30
50-3/8
A36, 42
63
Warning:
Mount the indoor unit on a ceiling strong enough to withstand the weight of
the unit.
2.2. Outline dimensions (Outdoor unit)
Refer to the outdoor unit installation manual.
3.1. Check the indoor unit accessories (Fig. 3-1)
The indoor unit should be supplied with the following accessories
(contained in the inside of the intake grille).
Accessory name
Washer
4 pcs
Pipe cover
1 pc Large size (For gas tubing)
Pipe cover
1 pc Small size (For liquid tubing)
Band
4 pcs
Joint socket
1 pc Marked with "UNIT"
Socket cover
1 pc
Drain tubing cover
1 pc
3.2. Preparation for installation (Fig. 3-2)
3.2.1. Suspension bolt installing spacing
(inch)
Models
A
B
A24,30
48-11/16
50-3/8
A36,42
61-5/16
63
3.2.2. Refrigerant and drain tubing location
Front side outlet
Left side outlet
Right side outlet
Independent piece (Removable)
Right drain tubing
In case of the rear pipe arrangement, make sure to remove the shaded portions
from the
independent piece. Then put the
position.
(The heat exchanger might be clogged because of dust)
3.2.3. Selection of suspension bolts and tubing positions (Fig. 3-3)
Caution:
Install the indoor unit at least 8 ft. (2.4 m) above floor or grade level. These
appliances are not accessible to the general public.
Using the pattern paper provided for installation, select proper positions for suspen-
sion bolts and tubing and prepare relative holes.
Pattern paper
Suspension bolt hole
Indoor unit width
Secure the suspension bolts or use angle stock braces or square timbers for bolt
installation.
Use inserts of 220-230 lbs. (100-105 kg) each.
Use suspension bolts of W 3/8 or M10 in size.
(inch)
Q'ty
Left drain tubing
Gas tubing
Liquid tubing
Rubber plug
with Joint socket
independent piece back in initial
3

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents