Advertisement

NETWORK
Page name
Item
Page No.
<PTP STATUS>
PTP NIC
N05
Displayed only when
HKCU-SFP50 is installed.
PORT
Network Status
<IP LIVE>
IP LIVE SYSTEM MANAGER
N06
Displayed only when
HKCU-SFP50 is installed.
MULTICAST
ADDRESS
HITLESS FAILOVER
Set value
LAN1, LAN2
STATUS
NO MASTER, LOCKED,
LOCKING, NOT IN USE
LAN1, LAN2
UTC Time
1970-01-01 00:00:00
MasterID
0000000000000000-0
GMClockID
0000000000000000-0
Sync
0Hz (0pkts)
FollowUp
0Hz (0pkts)
DelayReq
0Hz (0pkts)
DelayResp
0Hz (0pkts)
UNAVAILABLE, NOT GOOD,
GOOD, VERY GOOD
Delay
0ns
Jitter
0ns
PORT
DISABLE, LAN1&LAN2
DHCP
OFF
PRIMARY IP
0.0.0.0 to 255.255.255.255
ADDRESS
SECONDARY IP
0.0.0.0 to 255.255.255.255
ADDRESS
PRIMARY
DISCONNECTED, CONNECTING,
CONNECTION
CONNECTED
STATUS
SECONDARY
DISCONNECTED, CONNECTING,
CONNECTION
CONNECTED
STATUS
AUTO, MANUAL
ON, OFF
Description
Displays the port on which PTP is running.
Displays the PTP status.
NOT IN USE: PTP operation stopped
NO MASTER: PTP master not found
LOCKING: Synchronizing
LOCKED: Synchronized
Selects the port for which to display the status.
Master time (displays the internal time when the
master is Free-run or Disable).
Displays the master clock ID.
Displays the grandmaster clock ID.
Displays the sync message rate.
Displays the follow-up message rate.
Displays the delay request message rate.
Displays the delay response message rate.
Displays the network status.
Displays the network delay.
Displays the network jitter.
Sets the IP Live System Manager (LSM).
DISABLE: Does not communicate with LSM.
LAN1&LAN2: Communicates with LSM using LAN1
and LAN2 (for redundancy).
Note
Restart the unit after changing the PORT setting.
Sets the IP address of the LSM (fixed OFF).
Sets the IP address of LSM1.
Sets the IP address of LSM2.
Displays the status of the connection with LSM1.
DISCONNECTED: Disconnected.
CONNECTING: Establishing communication.
CONNECTED: Communication established.
Displays the status of the connection with LSM2.
DISCONNECTED: Disconnected.
CONNECTING: Establishing communication.
CONNECTED: Communication established.
Sets the mode switching method for the multicast
address setting of IP stream.
Fixed to AUTO when PORT is set to LAN1&LAN2,
and uses multicast addresses configured from the
LSM.
Fixed to MANUAL when PORT is set to DISABLE,
and uses the addresses set manually using the
MULTICAST ADDRESS 1 to 5 pages.
Enables/disables IP stream redundancy.