AUDIO/INTERCOM Menu

AUDIO/INTERCOM
Page name
Item
Page No.
<MIC GAIN>
CAM MIC GAIN
A01
<AUDIO OUT>
DELAY
A02
AES/EBU OUT
ANALOG OUT
<INTERCOM>
INTERCOM CH
A03
PRODUCER
INTERFACE
ENGINEER
INTERFACE
PGM1 INPUT LEVEL
PGM2 INPUT LEVEL
PGM3 INPUT LEVEL
Set value
CH1
(---), 20, 30, 40, 50, 60 dB
CH2
(---), 20, 30, 40, 50, 60 dB
0, 5, 11, 16, 21, 27, 32, 37, 43, 48,
53, 59, 64, 69, 75, 80 ms
MIC1/2, AES/EBU
MIC1/2, AES/EBU
CH1 : LEVEL
–20, 0, +4 dBu
CH1 : ADJUST
–99 to 99, 0
CH2 : LEVEL
–20, 0, +4 dBu
CH2 : ADJUST
–99 to 99, 0
1CH(PROD), 2CH(PROD&ENG)
CLEAR COM, 4WIRE, RTS
SIDE TONE
–99 to 99 0
CANCEL
TERMINATION
OFF, ON
CLEAR COM, 4WIRE, RTS
SIDE TONE
0 to 99 0
CANCEL
TERMINATION
OFF, ON
–20, 0, +4 dBu
–20, 0, +4 dBu
–20, 0, +4 dBu
Description
Sets the camera microphone gain.
Set according to the microphone used.
(---): Displayed when a camera is not connected
(Display only).
Sets the camera microphone output phase.
Selects the AES/EBU output.
MIC1/2: Outputs the camera MIC1/2 input from the
AES/EBU connector of the CCU.
AES/EBU: Outputs the camera AES/EBU input from
the AES/EBU connector of the CCU.
Selects the MIC OUT ANALOG output.
MIC1/2: Outputs the camera MIC1/2 input from the
AUDIO OUT connector of the CCU.
AES/EBU: Outputs the camera AES/EBU input from
the AUDIO OUT connector of the CCU.
Sets the AUDIO CH1 output level.
Sets the AUDIO CH2 output level.
Selects the intercom channel number to be used.
Sets the producer line intercom system.
Sets the side tone cancel level. (Setting is possible
when CLEAR COM or RTS is selected)
Sets termination resistance (200 ohms). (Setting is
possible when CLEAR COM or RTS is selected)
OFF: Displayed when 4WIRE is selected in
PRODUCER INTERFACE (Display only).
Sets the engineer line intercom system.
Sets the side tone cancel level. (Setting is possible
when CLEAR COM or RTS is selected)
Sets termination resistance (200 ohms). (Setting is
possible when CLEAR COM or RTS is selected)
OFF: Displayed when 4WIRE is selected in
ENGINEER INTERFACE (Display only).
Sets the PGM1 input level.
Sets the PGM2 input level.
Sets the PGM3 input level.