Download Print this page

CEM Systems Compact Door Interface Unit DIU 200 Specification

Compact door interface unit

Advertisement

Quick Links

DIU 200 Module
Compact Door Interface Unit
OVERVIEW
The Compact Door Interface Unit (DIU 200) is designed primarily to provide power
to a door lock, as well as local power to a CEM reader when a high level of security
is required. It has onboard inputs which can be used to monitor conditions such as
a fire alarm or activated break-glass condition.
The DIU 200 improves door security, by allowing the installer to locate lock
controls on the secure side of a door, with an intelligent CEM reader on the
unsecured side. The DIU 200 communicates with an intelligent CEM reader over
a single pair RS485 cable. Upon a valid swipe at the card reader, the reader
will instruct the DIU (over the RS485 communications channel) to activate the
appropriate output to release the lock using a coded data signal (i.e. coded lock).
As an added benefit, the DIU 200 monitors the status of all standard door
monitoring inputs; inputs on an intelligent CEM reader are free for use as general
purpose inputs.
DIU 200 Module
www.cemsys.com
1. DIU Unit Enclosure
2. CEM Reader
3. Sounder
4. Break Glass Unit
5. REX/ Exit Reader or
Secure side push button
6. Door Holder (via optional Backplane)
7. Door Lock
8. Lock Sense
9. Door Position sensor
FEATURES
• Door Interface Electronics
held on one board
• Provides 'coded lock' serial
interface between door
hardware and card reader
• On site selectable for 12 or
24 volt lock output
• Fire alarm and break glass
inputs for emergency door
release
• Designed for ease
of installation and
maintenance using 2 part
connectors throughout
• Compliant with EN55022
(emissions) and EN55024
(access control immunity)
• Backup battery connection
for emergency power
(optional)

Advertisement

loading

Summary of Contents for CEM Systems Compact Door Interface Unit DIU 200

  • Page 1 DIU 200 Module Compact Door Interface Unit OVERVIEW The Compact Door Interface Unit (DIU 200) is designed primarily to provide power to a door lock, as well as local power to a CEM reader when a high level of security is required.
  • Page 2: Technical Specifications

    Interfaces The DIU 200 Module provides direct interfaces to the following devices: • CEM Card Reader • Electric Door Lock • Fire Alarm System • Break Glass Unit • Exit Push Button • Inputs from alarm devices Up to 8 inputs can be wired from alarm/status monitoring devices directly to the DIU 200 module.

This manual is also suitable for: