Troubleshooting; Specifications - JVC VF-HP900G Instructions Manual

Studio viewfinder
Hide thumbs Also See for VF-HP900G:
Table of Contents

Advertisement

Troubleshooting

Troubleshooting
Power does not turn on
No video image

Specifications

General
Item
Device to be connected
Power
Rated current
Allowable operating temperature
Allowable operating humidity
Mass
LCD Specifications
Item
Screen size
Aspect ratio
Resolution
Effective screen dimensions
Viewing angle (TYP.)
Luminance
Contrast ratio
Input/Output Terminal
Item
Video
HDMI
SDI IN
SDI OUT
VF CABLE
Audio
PHONE
Data
USB
Power
DC IN
20
Others
Ensure that the VF cable and power cable are plugged in securely. Turn
on the power of the camera.
Check the position of the power switch at the back of this unit.
Ensure that the VF cable is plugged in securely.
Turn on the power of the camera and configure correctly.
GY-HC900
DC 12 V (10.5 V to 17 V)
1.4 A (DC 12 V)
0 °C to 40 °C (32 °F to 104 °F)
30 %RH to 80 %RH
1.0 kg
7.0 inch
16:10
WUXGA (1920×1200) 8 bit
15.1 cm (width), 9.8 cm (height), 18.0 cm (diagonal)
Horizontal: 160°, Vertical: 160°
450 cd/m
1100:1
Terminal
HDMI signal input (HDCP-compatible, linear PCM): HDMI
connector x 1
Digital signal input (3G/HD/SD SDI, supports embedded audio):
auto detection, BNC connector x 1
Digital signal output (3G/HD/SD SDI, supports embedded
audio): BNC connector x 1
26-pin connector (terminal used exclusively for camera: video,
audio, power, control) x 1
Φ3.5 mm stereo mini jack x 1
USB2.0 type A x 1
XLR 4-pin DC12 V (10.5 V to 17 V) x 1