Commissioning; Separator Commissioning; Commissioning Participants; Separator Contents Disposal - Kessel NS 1 Installation And Operating Instructions Manual

Grease separator euro “g” for underground installation
Table of Contents

Advertisement

Available languages

Available languages

4.1 Separator commissioning

Before the separator is put into service please make sure that:
- The separator is completely clean, including inlet and outlet,
and that the interior of the chamber is free of dirt and debris.
- The cleaned separator is completely filled with clean cold
water up to the outlet.

4.2 Commissioning participants

The commissioning of the separator is usually handled by a tra-
desman although this can be handled by a KESSEL contractor
or KESSEL employee if desired.
1) The following people should be on hand during the commis-
sioning:
- Building contractor representative
- Plumber / tradesman who will be maintaining the separator
- Building maintenance personnel
- Disposal company who will be handling the disposal account
The first emptying (disposal) of the separator contents should
take place within 2 to 3 weeks from the day the separator was
placed into service.
Disposal intervals
According to DIN V 4040-2, it is advised that sludge and grease
separators should be fully emptied, cleaned and refilled with
cold fresh water at fourteen day intervals or at least on a month-
ly basis. In order for a grease separator to function as designed,
it is very important that the separator is emptied at regular in-
tervals as described above. Due to this, it is recommended that
a licensed disposal company is contracted to empty the sepa-
rator at regular intervals and during times when strong odours
will not present a problem. During disposal of DIN 4040 under-
ground grease separators, first the grease separation compart-
ment must be emptied and than the sludge compartment. This
prevents any flotation of integrated sludge compartment.

4. Commissioning

5. Separator contents disposal

29
2) Commissioning preparation
- Separator is completely filled with clean water
3) Commissioning
- Separator to be checked for watertightness and for proper
functionality
- Contents of this user's manuals to be discussed with those
present
4) Transfer of this manual to the appropriate personnel
4.3 Handover certificate
Disposal procedure
• Remove manhole cover.
• Place disposal truck's suction hose inside separator and re-
move entire contects of chamber. CAUTION: Dispose the
Grease Separation area first and then the sludge trap.
• Rinse and clean interior walls of chamber.
Remove coagulated fat/oil and debris.
• Refill chamber with cold clean water. CAUTION: Fill first the
sludge trap than the grease separation area.
• Clean and grease all accessible seals. Replace seals if ne-
cessary.
• Replace cover(s) and secure with cover clamps.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ns 2Ns 4

Table of Contents