Output specifications
■Relay output (FX-16EYR-TB, FX-16EYR-ES-TB/UL)
Item
Output type
External voltage
Max. load
Resistance load
Inductive load
Min. load
Open circuit leakage current
Response time
ON voltage of output element
Output circuit insulation
Indication of output operation
Power consumption
Input/output configuration circuit
Unsupported applications
APPX
170
Appendix 6 Terminal Module
Specifications
Relay
250 V AC or less, 30 V DC or less
2 A/point
80 VA
5 V DC, 2 mA (reference values)
Approx. 10 ms
1.5 V
Mechanical insulation
LED is lit when the power is supplied to relay coils.
1.92 W (80 mA 24 V DC)
FX-16EYR-TB
CN1
connector
FX-16EYR-ES-TB/UL
CN1
connector
side
Positioning, Pulse Y Output ((D)PLSY) instruction, Pulse Width Modulation ((D)PWM) instruction,
ABS Current Value Read (DABS) instruction, Start/stop of high-speed I/O function ((D)HIOEN)
instruction, Input Matrix (MTR) instruction, Digital Switch (DSW) instruction, Seven Segment With
Latch (SEGL) instruction
The total load current per common terminals (four points) should be 8 A or less.
24 V DC 5 mA
24+
side
LED
24 V DC 5 mA
24-
LED
0 to 7
Fuse
COMn
External wiring
0 to 7
Fuse
COMn
External wiring

Hide quick links: