When BIN instructions are used
Examples of wiring for capturing values from a 2-digit digital switch to the data register D102 are given below.
For the instructions, refer to MELSEC iQ-F FX5 Programming Manual (Instructions, Standard Functions/Function Blocks).
■Example of program
SM400
BIN
K2X10 D102
■Example of wiring
• Sink wiring
The example is the wiring for the input/output of the FX5UJ-40MT/ES.
S/S
0V
24V
• Source wiring
The example is the wiring for the input/output of the FX5UJ-40MT/ESS.
S/S
0V
24V
0
1
10
10
1
2
4
8
1
X10
X11
X12
X13
X14
Sink input
0
1
10
10
1
2
4
8
1
X10
X11
X12
X13
X14
Source input
2
4
8
X15
X16
X17
FX5UJ-40MT/ES
2
4
8
X15
X16
X17
FX5UJ-40MT/ESS
6.7 Examples of Wiring for Various Uses