Operation - Makita DHR280 Instruction Manual

Cordless combination hammer
Hide thumbs Also See for DHR280:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
NOTE: If you connect a vacuum cleaner to the dust
cup set, remove the dust cap before connecting it.
► Fig.27: 1. Dust cap
To remove the dust cup set, remove the bit while pulling
the chuck cover in the direction of the arrow.
► Fig.28: 1. Bit 2. Chuck cover
Hold the root of dust cup and pull it out.
► Fig.29
NOTE: If the cap comes off from the dust cup, attach
it with its printed side facing up so that groove on the
cap fits in the inside periphery of the attachment.
► Fig.30

OPERATION

CAUTION:
Always use the side grip (auxiliary
handle) and firmly hold the tool by both side grip
and switch handle during operations.
CAUTION:
Always make sure that the work-
piece is secured before operation.
CAUTION:
Do not pull the tool out forcibly
even the bit gets stuck. Loss of control may
cause injury.
CAUTION:
The dust collection system is
intended for drilling in concrete only. Do not use
the dust collection system for drilling in metal or
wood.
CAUTION:
When using the tool with the dust
collection system, be sure to attach the filter
to the dust collection system to prevent dust
inhalation.
CAUTION:
Before using the dust collection
system, check that the filter is not damaged.
Failure to do so may cause dust inhalation.
CAUTION:
The dust collection system col-
lects the generated dust at a considerable rate,
but not all dust can be collected.
NOTICE:
Do not use the dust collection system
for core drilling or chiseling.
NOTICE:
Do not use the dust collection system
for drilling in wet concrete or use this system
in wet environment. Failure to do so may cause
malfunction.
NOTE: If the battery cartridge is in low temperature,
the tool's capability may not be fully obtained. In this
case, warm up the battery cartridge by using the
tool with no load for a while to fully obtain the tool's
capability.
► Fig.31
Hammer drilling operation
CAUTION:
There is tremendous and sudden
twisting force exerted on the tool/drill bit at the time of
hole break-through, when the hole becomes clogged
with chips and particles, or when striking reinforcing
rods embedded in the concrete. Always use the side
grip (auxiliary handle) and firmly hold the tool by
both side grip and switch handle during opera-
tions. Failure to do so may result in the loss of control
of the tool and potentially severe injury.
Set the action mode changing knob to the
Position the drill bit at the desired location for the hole,
then pull the switch trigger. Do not force the tool. Light
pressure gives best results. Keep the tool in position
and prevent it from slipping away from the hole.
Do not apply more pressure when the hole becomes
clogged with chips or particles. Instead, run the tool at
an idle, then remove the drill bit partially from the hole.
By repeating this several times, the hole will be cleaned
out and normal drilling may be resumed.
NOTE: Eccentricity in the drill bit rotation may occur
while operating the tool with no load. The tool auto-
matically centers itself during operation. This does not
affect the drilling precision.
Chipping/Scaling/Demolition
Set the action mode changing knob to the
Hold the tool firmly with both hands. Turn the tool on
and apply slight pressure on the tool so that the tool will
not bounce around, uncontrolled.
Pressing very hard on the tool will not increase the
efficiency.
► Fig.32
Drilling in wood or metal
CAUTION:
Hold the tool firmly and exert care
when the drill bit begins to break through the
workpiece. There is a tremendous force exerted on
the tool/drill bit at the time of hole break through.
CAUTION:
A stuck drill bit can be removed
simply by setting the reversing switch to reverse
rotation in order to back out. However, the tool
may back out abruptly if you do not hold it firmly.
CAUTION:
Always secure workpieces in a
vise or similar hold-down device.
NOTICE:
Never use "rotation with hammering"
when the drill chuck is installed on the tool. The
drill chuck may be damaged.
Also, the drill chuck will come off when reversing the
tool.
NOTICE:
Pressing excessively on the tool will
not speed up the drilling. In fact, this excessive
pressure will only serve to damage the tip of your drill
bit, decrease the tool performance and shorten the
service life of the tool.
Set the action mode changing knob to the
17 ENGLISH
symbol.
symbol.
symbol.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dhr281Dhr282Dhr283

Table of Contents