Sirius Satellite Radio SIU3 Installation Instructions Manual

Sirius Satellite Radio SIU3 Installation Instructions Manual

Island

Advertisement

Quick Links

INSTALLATION
INSTRUCTIONS
CARE AND USE MANUAL FOR:
ISLAND RANGE HOODS
Models covered by this instructions:
SIU3, SIU5, SU404, SU405, SU401, SIU14, SIU24, SIU8
*** BEFORE INSTALLATION ***
ENSURE THERE IS NO VISIBLE OR HIDDEN DAMAGE
SUSTAINED DURING SHIPPING
*** SHIPPING DAMAGE ***
MUST BE REPORTED WITHIN 5 DAYS OF RECEIPT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIU3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sirius Satellite Radio SIU3

  • Page 1 INSTRUCTIONS CARE AND USE MANUAL FOR: ISLAND RANGE HOODS Models covered by this instructions: SIU3, SIU5, SU404, SU405, SU401, SIU14, SIU24, SIU8 *** BEFORE INSTALLATION *** ENSURE THERE IS NO VISIBLE OR HIDDEN DAMAGE SUSTAINED DURING SHIPPING *** SHIPPING DAMAGE ***...
  • Page 2 WAR NIN G Thank you for purchasing a Sirius Range Hood. Please read all the instructions in this manual before installing the appliance. Save these instructions for future reference. Only use this appliance as an exhaust ventilation system for the removal of coo- king vapors.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS BEFORE YOU BEGIN MINIMUM AND MAXIMUMS DUCTING Duct Run Calculation ELECTRICAL Electrical Supply INSTALLATION Structural preparation for the hood fan installation Fixing the Main Support Bracket Attaching the range hood to the ceiling Connecting Electricity and Ducting Re-Circulating Requirements Schematic of modular island components OPERATING PROCEDURES...
  • Page 4: Before You Begin

    B E F OR E Y OU B E G I N The manufacturer declines all responsibility BEFORE YOU BEGIN: It is advisable to in the event of failure to observe the instruc- test run the range hood before installa- tions given here for installation, maintenan- tion.
  • Page 5: Duct Run Calculation

    Duct Run Calculation. Maximum Run The maximum duct run before effecting the performance of the hood is 100’. Calculate 6” or 3 1/4 x 10” duct * 100 FT your duct run by measuring linear feet and adding the elbows, transitions and caps ba- Deduct sed on the table below.
  • Page 6: Installation

    I N S TA L L AT IO N Structural Preparation for the Hood Fan Do not switch on the lights with the hood flat Installation. on any surface as the in-tense heat will burn The island hood weighs approximately 125 the surface and destroy the lamps.
  • Page 7: Attaching The Range Hood To The Ceiling

    - use DUCT TAPE. This is of utmost importance - do not go any Only for SU 401,SIU3, SIU5, SIU14, SIU24: further until this has been tested and double Install the glass as per the instructions con- checked - the installer has sole responsibi- tained in the packaging of the glass.
  • Page 8: Connecting Electricity And Ducting

    This will require two strong people –do not attempt this step on your own. Bracket “B” has slots, position C per Diagram “A” (refer to page 5), at the top that will receive the spring clips located on Bracket “A” - THIS IS A TEMPORARY HOLD ONLY - DO NOT RELY SOLELY ON THESE CLIPS TO HOLD THE HOOD UP - THEY WON’T.
  • Page 9: Schematic Of Modular Island Components

    Bracket Deflector FOR SU405 Part B Deflector FOR SIU3, SIU5 Deflector attaches to ceiling mount bracket when island hood is installed in re-circu- lating mode and the air that has passed through the fat and carbon filters is returned to the room via a short length of 6” round ductwork attached to the power unit and...
  • Page 10 Diagram b – Securing Bracket “A” to “B” Please note – this is critically important - do not rely on the spring clips. Diagram A – Main Assembly FOR SU404...
  • Page 11: Operating Procedures

    Read all the instructions before operating FUNCTION the appliance. Save these instructions for future reference. SIU3 – SIU5 (Fig.3) A: Light ON/OFF button General Advice. B: Blower Speed 1 (low) or OFF Ensure that the grease filters are in place.
  • Page 12 SU401 - SU404 – SU405 Generating a new transmission code: The radio control system is provided with preset codes. Should new codes be required, proceed RC001 as follows: Press simultaneously buttons: ADIO ONTROL Radio control used for the remote operation of ducted cooker hoods.
  • Page 13 WARNING The battery should be replaced every year to guarantee the optimal range of the transmitter. To replace the exhausted battery, take the pla- stic lid off, remove the battery and replace it with a new one, observing the correct battery polarities.
  • Page 14: Maintenance

    Warning The battery should be replaced Filter requires washing indicator: after 30 every year to guarantee the optimal range hours of use, all the buttons will light up to of the transmitter. To replace the exhau- remind you that the grease filter should be sted battery, take the plastic lid off, remo- cleaned.
  • Page 15: Substitution Of The Led Bar

    LED bar with fig. 5 same characteristics. FOR SIU3 – SIU5 – SIU14 To replace the round LED lamps (fig. 6) you have to check first if it is possible to access the back side of the lamp with your hand.
  • Page 16: Warranty

    Three Year Limited Warranty YOU MUST REGISTER THE PURCHASE OF YOUR PRODUCT ON LINE AT www.siriuscappe.com/usa/warranty.htm TO CONVALIDATE YOUR WARRANTY. YOU CAN FIND THE DATA OF YOUR HOODS ON A LABEL INSIDE THE HOOD. JUST REMOVE THE GREASE FILTER TO READ IT. WARRANTY SERVICE To qualify for warranty service, you must notify Sirius After sale service at the email address stated below or call toll free USA 1-877-474-8770 and provide the model number, description...

This manual is also suitable for:

Siu5Su404Su405Su401Siu14Siu24 ... Show all

Table of Contents