Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 207

Motion module instructions, standard functions/ function blocks
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Ex.
[Label definitions]
Label name
TIMER_CONT_FB_M_1
i_Coil_B
o_ValueOut_I
o_Status_B
[Program]
TIMER_CONT_FB_M_1(
Coil := i_Coil_B ,
Preset := 200 ,
ValueIn := 0 ,
ValueOut => o_ValueOut_I ,
Status => o_Status_B );
[Timing chart]
ON
i_Coil_B
OFF
o_ValueOut_I
0
1
o_Status_B
OFF
Operation error
There is no operation error.
Data type
TIMER_CONT_FB_M
Bit
Word (signed)
Bit
15s
5s
...
...
150
151
200
ON
Class
VAR
VAR
VAR
VAR
19 TIMER FUNCTION BLOCKS
Description
An instance of standard FB
Executing condition (TRUE:
Execution, FALSE: Stop)
Timer current value
Output
205
19.4 Timer Function Block
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents