Sia - Intelliknight / Panels Pi Modifier Reporting - Honeywell Farenhyt Series Installation And Operation Manual

Addressable fire alarm control system emergency communication system
Hide thumbs Also See for Farenhyt Series:
Table of Contents

Advertisement

Event Description
System-based Wireless Gateway
Trouble
System-based Wireless Gateway
Trouble - restore
Wireless Gateway Trouble
Wireless Gateway Trouble re-
store

12.2 SIA - IntelliKnight / Panels PI Modifier Reporting:

Events are sent to the central station as a variable length string:
The event format is:
EEZZZZ
Where:
EE
Event code (2 characters)
ZZZZ Event parameter (up to four digits – not zero filled)
1.
The account number is sent using an account block that is separate from the event block
2.
Multiple events can be sent within a single event block. Events are separated by a "/" character.
3.
Event parameter can be either a zone, point or module number.
4.
When reporting by point is enabled, the communicator uses a "pi" event to supersedes the actual point event to report the module
the point is linked to.
5.
Panel ID is not sent in the SIA event parameters.
For Example see Table 12.4:
Fire Alarm-Zone
Fire Alarm-Zone
Fire Alarm-Point
Fire Alarm-Point
Expander Trouble
Auto Test
Battery Trouble-Panel 32
Battery Trouble-Expander
18
SLC Loop Shorted
Program Begin Panel
ID=32
Program Begin Panel ID=
22
AC Power Loss - Panel 22
171
SIA Reporting Format
SIA pi Modifier
Module
SIA
ID # (If
Event
Any)
Codes
pi Exp. ID UT
pi Exp. ID UJ
pi Exp. ID UT
pi Exp. ID UJ
Table 12.3 : Report Formats Table
Event
Zone
n/a
Zone
n/a
Point
n/a
Point
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Table 12.4 SIA- Panels - PI Modifier Reporting Examples
IFP-300 / IFP-300ECS Manual P/N LS10145-001SK-E:B 12/18/2017
SIA
Parameter Fixed Length
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
Point #
UTNNXXPPPP
Point #
UJNNXXPPPP
Point #
UTNNXXPPPP
Point #
UJNNXXPPPP
n/a97
15
n/a
n/a
05
n/a
01
n/a
123
33
n/a
203
11
n/a
n/a
n/a
n/a
n/a
98
n/a
n/a
18
n/a
n/a
44
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
98
n/a
n/a
Contact ID Reporting Format
Qualifier
Event
Group #
Code
1
373
Exp. ID
3
373
Exp. ID
1
373
Exp. ID
3
373
Exp. ID
EE-ZZ
FA15
EE-Z
FA5
EE-ZZ /EE-
pi01/FA123
ZZZ
EE-ZZ /EE-
pi11/FA203
ZZZ
EE-ZZ
ET11
EE-Z
RP0
EE-ZZ
YT98
EE-ZZ
YT18
EE-ZZ
ET44
EE-Z
LB0
EE-Z
LB0
EE-Z
AT0
Contact #
Point #
Point #
Point #
Point #

Advertisement

Table of Contents
loading

This manual is also suitable for:

Farenhyt ifp-300Farenhyt ifp-300ecs

Table of Contents