Event Description
Point Events
An unexpected SLC device has
been detected
An unexpected SLC device has
been removed
Auxiliary power disabled
Auxiliary power enabled
Auxiliary power Trouble
Auxiliary power trouble restore
Background Music Switch is
Trouble
Background Music Switch is
Trouble Restored
Background Music Switch is
Disabled
Background Music Switch is
Enabled
CO Detector Trouble
CO Detector Trouble Restore
CO Detector Disabled
CO Detector Enabled
Detector Alarm
Detector Alarm restore
Detector Disabled
Detector Enabled
Detector Trouble
Detector Trouble restore
Detector CO Alarm
Detector CO Alarm Restore
Detector CO Supervisory Alarm
Detector CO Supervisory Alarm
Restore
ECS Alarm # Point Alarm
ECS Alarm # Point Alarm Restore pi Exp. ID QH
ECS Alarm # Point Trouble
ECS Alarm # Point Trouble Re-
store
ECS Alarm # Point Disabled
IFP-300 / IFP-300ECS Manual P/N LS10145-001SK-E:B 12/18/2017
SIA Reporting Format
SIA pi Modifier
Module
SIA
Parameter Fixed Length
ID # (If
Event
Any)
Codes
For IDP/SK devices, sensors 1–159 are reported as Points 1–159, modules 1–159 are
reported as Points 201–359.
pi Exp. ID XE
Point #
pi Exp. ID XI
Point #
pi Exp. ID FB
Point #
pi Exp. ID FU
Point #
pi Exp. ID FT
Point #
pi Exp. ID FJ
Point #
pi Exp. ID UT
Point #
pi Exp. ID UJ
Point #
pi Exp. ID UB
Point #
pi Exp. ID UU
Point #
pi Exp. ID GT
Point #
pi Exp. ID GJ
Point #
pi Exp. ID GB
Point #
pi Exp. ID GU
Point #
pi Exp. ID FA
Point #
pi Exp. ID FH
Point #
pi Exp. ID FB
Point #
pi Exp. ID FU
Point #
pi Exp. ID FT
Point #
pi Exp. ID FJ
Point #
pi Exp. ID GA
Point #
pi Exp. ID GH
Point #
pi Exp. ID GS
Point #
pi Exp. ID GR
Point #
pi Exp. ID QA
(EPPP) E -
Emergen-
cy #
PPP -
Point #
(EPPP) E -
Emergen-
cy #
PPP -
Point #
pi Exp. ID QT
Point #
pi Exp. ID QJ
Point #
pi Exp. ID QB
Point #
Table 12.3 : Report Formats Table
Contact ID Reporting Format
SIA
Qualifier
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
XENNXXPPPP
1
XINNXXPPPP
3
FBNNXXPPPP
1
FUNNXXPPPP
3
FTNNXXPPPP
1
FJNNXXPPPP
3
UTNNXXPPPP
1
UJNNXXPPPP
3
UBNNXXPPPP
1
UUNNXXPPPP
3
GTNNXXPPPP
1
GJNNXXPPPP
3
GBNNXXPPPP
1
GUNNXXPPPP
3
FANNXXPPPP
1
FHNNXXPPPP
3
FBNNXXPPPP
1
FUNNXXPPPP
3
FTNNXXPPPP
1
FJNNXXPPPP
3
GANNXXPPPP
1
GHNNXXPPPP
3
GSNNXXPPPP
1
GRNNXXPPPP
3
QANNXXEPPP
1
QHNNXXEPPP
3
QTNNXXPPPP
1
QJNNXXPPPP
3
QBNNXXPPPP
1
Event
Group #
Contact #
Code
380
Exp. ID
Point #
380
Exp. ID
Point #
571
Exp. ID
Point #
571
Exp. ID
Point #
320
Exp. ID
Point #
320
Exp. ID
Point #
379
Exp. ID
Point #
379
Exp. ID
Point #
580
Exp. ID
Point #
580
Exp. ID
Point #
373
Exp. ID
Point #
373
Exp. ID
Point #
571
Exp. ID
Point #
571
Exp. ID
Point #
110
Exp. ID
Point #
110
Exp. ID
Point #
571
Exp. ID
Point #
571
Exp. ID
Point #
373
Exp. ID
Point #
373
Exp. ID
Point #
162
Exp. ID
Point #
162
Exp. ID
Point #
200
Exp. ID
Point #
200
Exp. ID
Point #
220 +
Exp. ID
Point #
Emer-
gency #
220 +
Exp. ID
Point #
Emer-
gency #
242
Exp. ID
Point #
242
Exp. ID
Point #
243
Exp. ID
Point #
166

Advertisement

Table of Contents
loading

This manual is also suitable for:

Farenhyt ifp-300Farenhyt ifp-300ecs

Table of Contents