5: Terms Used In This Manual; Compatible Products - Honeywell Farenhyt Series Installation And Operation Manual

Addressable fire alarm control system emergency communication system
Hide thumbs Also See for Farenhyt Series:
Table of Contents

Advertisement

• Supports up to eight ECS-50W, ECS-125W, ECS-INT50W, or ECS-DUAL50W Addressable Amplifiers for a maximum of 1000
watts per system
• Support for dual channel and backup audio using the ECS-DUAL50W amplifier and ECS-50WBU back-up amplifier.
1.1.5 Terms Used in this Manual
The following terminology is used with the IFP-300 / IFP-300ECS system:
Term
SLC
Module
Input Point
Input Zone
Output Point
(or Output Circuit)
Output Group (OPG)
Output (or "Cadence") Pattern
Mapping
ECS
Networking
Network System
SWIFT

1.2 Compatible Products

The chart below lists the products available from Honeywell for use with the IFP-300.
Type of Device
IDP Addressable SLC Devices
SK Addressable SLC Devices
SD Addressable SLC Devices
SWIFT Wireless SLC Devices
Other Modules
IFP-300 / IFP-300ECS Manual P/N LS10145-001SK-E:B 12/18/2017
Signaling Line Circuit
The term module is used for all hardware devices except for SLC addressable devices and
notification appliances. This includes the IFP-300 panel itself.
An addressable sensing device, such as a smoke or heat detector or a contact monitor
device.
A protected area made up of input points.
A notification point or circuit for notification appliances. Relay circuits and auxiliary power
circuits are also considered output points.
A group of output points. Operating characteristics are common to all output points in the
group.
The pattern that the output will use, for example, Constant, March Code, ANSI 3.41. Applies
to zones and special system events. See "Cadence Patterns" on page 199 for additional
information.
Mapping is the process of specifying which outputs are activated when certain events occur
in the system. Section 8.2 explains mapping in detail.
Emergency Communication System
Up to 32 panels can be networked.
Consist of any combination of 32 panels of these model numbers: IFP-75, IFP-300, IFP-
300ECS, IFP-2100 or IFP-2100ECS.
Smart Wireless Integrated Fire Technology
Model
See Section 7.1 for a list of compatible devices
See Section 7.2 for a list of compatible devices
See Section 7.3 for a list of compatible devices
See Section 7.4 for a list of compatible devices
5824 Serial/Parallel
Allows a printer to be attached for the system for on-site event logging. Four
Printer Interface Module
maximum per system.
5815XL (Rev H or above)
Allows up to 127 SD devices to be added to the system. The number of
SLC Expander
5815XLs that can be added to the system is limited only by the maximum
number of SBUS devices. However the maximum point count is limited to 254
per panel. Supports SD protocol devices only.
6815 SLC Expander
Supports System Sensor Devices (IDP or SK) only. Each 6815 supports up to
159 IDP or SK sensors and 159 IDP or SK modules. Maximum point count is
300 per panel.
RPS-1000 (Rev F or
Provides additional power, six Flexput™
higher) Intelligent Power
circuits, and two Form C relays.
Supply
5496 (Rev F or above)
Add 4 Notification/Auxiliary power circuits
NAC Expander
with each 5496 Intelligent Power Module
RA-2000 Remote LCD
4x 40 Remote LCD annunciator, can be used in any combination, up to a total
Annunciator
of 16 devices on one panel.
RA-100 Remote LCD
4 x 20 Remote LCD annunciator, can be used in any combination, up to a total
Annunciator
of 16 devices on one panel.
Table 1.1 IFP-300 Compatible Products
Description
Description
RPS-1000s and 5496s can be
used in any combination, up to
a total of 16 on one system
2