tains powder particles, but also performs an efficient antibacte-
rial action. In addition, it greatly reduces irritants such as pollen
and spores. The filter is treated with small particles of silver (with
dimensions equal to millionths of a millimeter) which are able to
block the multiplication of bacteria and spores when in contact
with them, and therefore encourage their destruction.
CHECKS AT THE START OF THE SEASON
Make sure the power cord and socket are in perfect condition
and make sure the earthing system is efficient. Comply strictly
with the installation standards.
END OF SEASON OPERATIONS
To completely drain the water from the internal circuit, remove
the cap from the outside of the drainage hose, turning it coun-
ter clockwise. Then remove the internal cap (fig. 10). Drain the
water completely into a basin.When it is completely drained,
replace the caps, making sure they are completely closed. Clean
the filter as indicated previously. The filter must be completely
dry before reinserting it.
10
When the appliance is empty, replace the caps.
Clean the filter and dry thoroughly before putting back.
In order to properly storage the appliance at the end of the sea-
son, we suggest you cover it with the supplied end of season
dust cover B9 and you put the accessories in the relevant
end of season accessories bag B10.

TECHNICAL SPECIFICATIONS

Power supply voltage
Max. absorbed power during air conditioning
Refrigerant
Cooling capacity

LIMIT CONDITIONS

Room temperature for
air conditioning
Room temperature for
heating
Transport, filling, cleaning, recovery and disposal of
refrigerant should be performed by a technical service
center appointed by the manufacturer only.
The appliance should be disposed of by a center appoint-
ed by the manufacturer only.
TO AVOID DAMAGE TO THE UNIT:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit
has been on its side, oil needs to return to the compressor to en-
sure proper function. Without allowing the unit this time (6-24
hours) the unit may function for only a short time, and then the
compressor will break down from lack of oil.
ELECTRICAL CONNECTION
This appliance is equipped with a 3 prong grounded plug. The
plug must be connected into an outlet that is properly installed
and grounded in the accordance with all local codes and ordi-
nances. Do not modify the plug provided with the appliance.
If it will not fit the outlet, have a proper outlet installed by a
qualified electrician or relocate the unit to a proper outlet. If the
household electrical supply does not meet the above specifica-
tions, or if you are not sure your home has an effective electrical
ground, have a qualified electrician or your local electrical utility
company check it and correct any problems.
SAFETY PLUG
The appliance is fitted with a safety plug to protect the power
cord. If power is cut off, unplug from the outlet and make sure
the power cord is undamaged. If the cord is damaged, call the
service center immediately. If power cuts off frequently and the
power cord is undamaged, contact a qualified electrician.
OPERATION OF THE SAFETY PLUG
see rating label
If the safety device incorporated in the plug trips and cuts off
"
the power supply, check that the power cord and plug are not
"
damaged. If the power cord is undamaged, to restore operation
"
press the "RESET" button. To verify correct operation of the plug,
press the "TEST" button periodically and make sure the appliance
disconnects. If this is not the case, contact the service center. To
restore operation, press the "RESET" button.
13
64 ÷ 95°F (18° ÷ 35°C)
50 ÷ 77°F (10 ÷ 25°C)

Advertisement