Kerosene Conversion Instructions for
Vitorondens 200-T 33kW, 40kW and 50kW

Isolate power supply and oil supply lines.

n
Set the burner into the servicing position as per boiler service
n
manual.
Loosen the 3 nuts securing the burner to the boiler door and
n
carefully withdraw the burner from the boiler.

Clean strainer, filter, fuel lines, and tank and remove water.

n
If the appliance is 40kW or 50kW Remove burner flame tube.
n

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vitorondens 200-T Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Viessmann Vitorondens 200-T Series

  • Page 1 Kerosene Conversion Instructions for Vitorondens 200-T 33kW, 40kW and 50kW Isolate power supply and oil supply lines. Clean strainer, filter, fuel lines, and tank and remove water. If the appliance is 40kW or 50kW Remove burner flame tube. Set the burner into the servicing position as per boiler service manual.
  • Page 2 Kerosene Conversion Instructions for Vitorondens 200-T 33kW, 40kW and 50kW Remove the 3 socket head bolts securing the mixing assembly cover to the front of the burner housing and slide the cover off the mixing assembly. Figure 1 - 40kW and 50kW appliance Figure 2- 33kW appliance...
  • Page 3 Kerosene Conversion Instructions for Vitorondens 200-T 33kW, 40kW and 50kW Remove nozzle as per Vitoflame 300 servicing instructions section “Nozzle Replacement” and replace with kerosene nozzle supplied in conversion kit. Figure 3 - 40kW and 50kW appliance Figure 4 - 33kW appliance Carefully disconnect the electrical connection plug from Fasten the cable tie supplied in the conversion kit around the the oil pre-heater and then plug the link wire supplied into...
  • Page 4 030F8922 030F8926 Pump Pressure bar (PSI) 9(131) 8 (116) 9 (131 Chamber pressure 11.5 11.3 11.5 13.6 13.4 13.8 Initial Installation air intake setting Viessmann Limited, Hortonwood 30, Telford Shropshire, TF1 7YP Tel. 01952 675000 Fax. 01952 675040 Email: info-uk@viessmann.com www.viessmann.co.uk...

Table of Contents